Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Querying and Redirecting the Serial Port (serialdir)

Querying and Redirecting the Serial Port (serialdir)

Function

The serialdir command is used to query and set serial port redirection.

Format

ipmcget -d serialdir

ipmcset -d serialdir -v <option>

Parameters

Parameter Description Value

<option>

Indicates the serial port to be used.

  • 0: sets the serial port on the server panel as the system serial port.
  • 1: sets the serial port on the server panel as the iBMC serial port.
  • 2: sets the SOL port as the system serial port.
  • 3: sets the SOL port as the iBMC serial port.
  • 4: sets the serial port on the SDI V3 card panel as an SCCL port.
  • 5: sets the serial port on the SDI V3 card panel as an IMU port.
  • 6: sets the serial port on the SDI V3 card panel as an SCCL port.
  • 7: sets the serial port on the SDI V3 card panel as an IMU port.

The value range of this parameter varies with the server model. Before setting the serial port, run the ipmcget -d serialdir command to query the value range of this parameter.

NOTE:
  • If no SDI V3 is installed in a server, <option> can be 0 to 3 only.
  • If one SDI V3 card is installed, the values 4 and 5 are available for setting the ports on the SDI V3 in I/O module 1 or 2.
  • If two SDI V3 cards are installed, the values 4 to 7 are available. The values 4 and 5 are used for setting the ports on the SDI V3 in I/O module 1, while the values 6 and 7 are for the ports on the SDI V3 in I/O module 2.

Usage Guidelines

  • The redirection setting of the SOL port takes precedence over the setting of the serial port on the server panel. If you redirect the SOL port to the system or iBMC serial port that is currently redirected from the serial port on the server panel, the serial port on the server panel will become unavailable temporarily. The serial port on the server panel will restore its original setting only after the SOL port is disconnected.
  • If the serial port (serial port on the panel or SOL serial port) is set as the system serial port, you can press Del during the OS startup process to enter the BIOS Setup screen.

Example

# Set the serial port on the server panel as the iBMC serial port.

iBMC:/->ipmcset -d serialdir -v 1
Set serial port direction successfully.

# Query the serial ports connected. The values of Num indicate the <option> values.

iBMC:/->ipmcget -d serialdir
Currently connected serial direction : 
Num           Source                  Destination         
1             PANEL COM               BMC COM   
4             SD100 PANEL COM5        SCCL COM5
Download