Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Configuration File Description

Configuration File Description

Table 9-1, Table 9-2, and Table 9-3 describe the parameters in iBMC, BIOS, and RAID controller card configuration files.

To ensure data security, some of the iBMC and RAID controller configuration in the configuration file imported after the mainboard replacement do not take effect.

Table 9-1 iBMC parameters

Type

Exported Parameter

Exported Subparameter

Description

Imported by Configuration File

Local user

User

UserName

Specifies the name of a user.

Supported

User

PassWord

Specifies the password of a user.

Not supported

Sensitive information is displayed in ciphertext in the configuration file.

User

Privilege

Specifies the rights of a user.

Supported

User

UserRoleId

Specifies the role of a user.

Supported

User

PermitRuleIds

Specifies the login rules for a user.

Supported

User

LoginInterface

Specifies the login interface for a user.

Supported

User

IsUserEnable

Specifies whether the user is enabled.

Not supported

The value is displayed in the configuration file.

User

IsUserLocked

Specifies whether the user is locked.

Not supported

The value is displayed in the configuration file.

UserRole

KVMMgnt

Specifies the KVM rights.

Supported

UserRole

UserMgnt

Specifies the user management rights.

Supported

UserRole

VMMMgnt

Specifies the VMM rights.

Supported

UserRole

BasicSetting

Specifies the rights for performing basic settings.

Supported

UserRole

ReadOnly

Specifies the read-only rights.

Supported

UserRole

PowerMgnt

Specifies the power control rights.

Supported

UserRole

DiagnoseMgnt

Specifies the debugging and diagnosis rights.

Supported

UserRole

ConfigureSelf

Specifies the rights for configuring the user's own data.

Supported

UserRole

SecurityMgnt

Specifies the security configuration rights.

Supported

Two-factor authentication

MutualAuthentication

MutualAuthenticationState

Specifies whether two-factor authentication is enabled.

Supported

MutualAuthentication

MutualAuthenticationOCSP

Specifies whether the two-factor authentication revocation check is enabled.

Supported

LDAP configuration

LDAP

Enable

Specifies whether LDAP is enabled.

Supported

LDAP

CertStatus

Specifies whether LDAP certificate verification is enabled.

Supported

LDAP

HostAddr

Specifies the LDAP server address.

Supported

LDAP

Port

Specifies the LDAPS port number.

Supported

LDAP

UserDomain

Specifies the domain name.

Supported

LDAP

Folder

Specifies the folder for which user applications are stored.

Supported

LDAP

BindDN

Specifies the distinguished name of an LDAP proxy user.

Supported

LDAP

BindDNPsw

Specifies the password of the LDAP proxy user.

Not supported

The value is displayed in the configuration file.

LDAPServer

Enable

Specifies whether LDAP is enabled.

Supported

LDAPServer

CertStatus

Specifies whether LDAP certificate verification is enabled.

Supported

LDAPServer

HostAddr

Specifies the LDAP server address.

Supported

LDAPServer

Port

Specifies the LDAPS port number.

Supported

LDAPServer

UserDomain

Specifies the domain name.

Supported

LDAPServer

Folder

Specifies the user application folder.

Supported

LDAPServer

BindDN

Specifies the distinguished name of an LDAP proxy user.

Supported

LDAPServer

BindDNPsw

Specifies the user password.

Not supported

The value is displayed in the configuration file.

LDAPGroup

GroupName

Specifies the LDAP group name.

Supported

LDAPGroup

GroupFolder

Specifies the application folder for an LDAP group.

Supported

LDAPGroup

GroupPermitRuleIds

Specifies the login rules for an LDAP group.

Supported

LDAPGroup

GroupLoginInterface

Specifies the login interface for an LDAP group.

Supported

LDAPGroup

GroupPrivilege

Specifies the rights of an LDAP group.

Supported

Security hardening

PasswdSetting

EnableStrongPassword

Specifies whether password complexity check is enabled.

Supported

SecurityEnhance

SSHPasswordAuthentication

Specifies whether SSH password authentication is enabled.

Supported

SecurityEnhance

UserInactTimeLimit

Specifies the time limit for which a user is inactive.

Supported

SecurityEnhance

PwdExpiredTime

Specifies the validity period of a password.

Supported

SecurityEnhance

MinimumPwdAge

Specifies the minimum validity period of a password.

Supported

SecurityEnhance

InitialPwdPrompt

Specifies whether to enable the function of prompting the user to change the password.

Supported

SecurityEnhance

ExcludeUser

Specifies the user who can log in to the system in emergencies.

Supported

SecurityEnhance

OldPwdCount

Specifies the previous password that cannot be used.

Supported

SecurityEnhance

AuthFailMax

Specifies the maximum number of failed login attempts allowed before a user account is locked.

Supported

SecurityEnhance

AuthFailLockTime

Specifies the user lockout period.

Supported

PermitRule

TimeRuleInfo

Specifies the rules for time-based logins.

Supported

PermitRule

IpRuleInfo

Specifies the rules for IP-based logins.

Supported

PermitRule

MacRuleInfo

Specifies the rules for MAC-based logins.

Supported

SecurityEnhance

PermitRuleIds

Specifies whether rules are enabled.

Supported

SecurityEnhance

BannerState

Specifies whether login security information configuration is enabled.

Supported

SecurityEnhance

BannerContent

Provides the login security information.

Supported

Network configuration

BMC

HostName

Specifies the iBMC host name.

Not supported

The value is displayed in the configuration file.

EthGroup

NetMode

Specifies the network port mode.

Supported

EthGroup

ActivePort

Specifies the management network port.

Supported

EthGroup

IpVersion

Specifies whether IP is enabled.

Supported

EthGroup

IpMode

Specifies how IPv4 addresses are assigned.

Supported

EthGroup

IpAddr

Specifies an IPv4 address.

Not supported

The value is displayed in the configuration file.

EthGroup

SubnetMask

Specifies an IPv4 subnet mask.

Not supported

The value is displayed in the configuration file.

EthGroup

DefaultGateway

Specifies the default IPv4 gateway IP address.

Not supported

The value is displayed in the configuration file.

EthGroup

Ipv6Mode

Specifies how IPv6 addresses are allocated.

Supported

EthGroup

Ipv6Addr

Specifies an IPv6 address.

Not supported

The value is displayed in the configuration file.

EthGroup

Ipv6Prefix

Specifies the prefix length of an IPv6 address.

Not supported

The value is displayed in the configuration file.

EthGroup

Ipv6DefaultGateway

Specifies the default IPv6 gateway IP address.

Not supported

The value is displayed in the configuration file.

DNSSetting

IPVer

Specifies the IP version bound with the DNS.

Supported

DNSSetting

Mode

Specifies how the DNS addresses are assigned.

Supported

DNSSetting

PrimaryDomain

Specifies the preferred DNS server.

Supported

DNSSetting

BackupDomain

Specifies the alternate DNS server.

Supported

DNSSetting

DomainName

Specifies the DNS domain name.

Supported

EthGroup

VlanState

Specifies whether VLAN is enabled.

Supported

EthGroup

VlanID

Specifies the VLAN ID.

Supported

NTP

EnableStatus

Specifies whether NTP is enabled.

Supported

NTP

Mode

Specifies the NTP mode.

Supported

NTP

PreferredServer

Specifies the address of the preferred NTP server.

Supported

NTP

AlternativeServer

Specifies the address of the alternate NTP server.

Supported

NTP

AuthEnableStatus

Specifies whether NTP server authentication is enabled.

Supported

NTP

MinPollInterval

Specifies the minimum NTP synchronization interval.

Supported

NTP

MaxPollInterval

Specifies the maximum NTP synchronization interval.

Supported

VNC

EnableState

Specifies whether VNC is enabled.

Supported

VNC

Password

Specifies the VNC password.

Not supported

Sensitive information is displayed in ciphertext in the configuration file.

VNC

Timeout

Specifies the validity period of the VNC password.

Supported

VNC

SSLEnableState

Specifies whether the SSL is enabled.

Supported

VNC

Port

Specifies the VNC service port number.

Supported

VNC

KeyboardLayout

Specifies the keyboard layout.

Supported

VNC

PermitRuleIds

Specifies the login rules.

Supported

BMC

TimeZoneStr

Specifies the time zone.

Supported

Service configuration

SSH

State

Specifies whether SSH is enabled.

Supported

SSH

Port

Specifies the SSH port number.

Supported

Snmp

State

Specifies whether SNMP Agent is enabled.

Supported

Snmp

PortID

Specifies the SNMP Agent.

Supported

Kvm

State

Specifies whether KVM is enabled.

Supported

Kvm

Port

Specifies the KVM port number.

Supported

Vmm

State

Specifies whether VMM is enabled.

Supported

Vmm

Port

Specifies the VMM port number.

Supported

Video

State

Specifies whether Video is enabled.

Supported

Video

Port

Specifies the Video port number.

Supported

WEBHTTP

State

Specifies whether HTTP is enabled.

Supported

WEBHTTP

Port

Specifies the HTTP port number.

Supported

WEBHTTPS

State

Specifies whether HTTPS is enabled.

Supported

WEBHTTPS

Port

Specifies the HTTPS port number.

Supported

RmcpConfig

LanState

Specifies whether IPMI LAN (RMCP) is enabled.

Supported

RmcpConfig

Port1

Specifies the IPMI LAN (RMCP) port 1.

Supported

RmcpConfig

Port2

Specifies the IPMI LAN (RMCP) port 2.

Supported

RmcpConfig

LanPlusState

Specifies whether IPMI LAN (RMCP+) is enabled.

Supported

System configuration

Snmp

V1State

Specifies whether SNMPv1 is supported.

Supported

Snmp

V2CState

Specifies whether SNMPv2c is supported.

Supported

Snmp

LongPasswordEnable

Specifies whether long passwords are enabled.

Supported

Snmp

ROCommunity

Specifies the read-only community string.

Not supported

Sensitive information is displayed in ciphertext in the configuration file.

Snmp

RWCommunity

Specifies the read-write community string.

Not supported

Sensitive information is displayed in ciphertext in the configuration file.

Snmp

RWCommunityState

Specifies whether the read/write community name is enabled.

Supported

Snmp

SNMPV1V2CPermitRuleIds

Specifies the SNMP login rules.

Supported

Snmp

AuthProtocol

Specifies the SNMPv3 authentication algorithm.

Supported

Snmp

PrivProtocol

Specifies the SNMPv3 encryption algorithm.

Supported

SecurityEnhance

TLSVersion

Specifies the TLS version.

Supported

SecurityEnhance

EnableUserMgnt

Specifies whether user management on the service side is enabled.

Supported

Session

Timeout

Specifies the timeout period for a web session.

Supported

Session

Mode

Specifies the web session mode.

Supported

BMC

LocationInfo

Specifies the equipment location.

Not supported

The value is displayed in the configuration file.

MeInfo

CpuUtiliseThre

Specifies the CPU usage alarm threshold.

Supported

MeInfo

MemUtiliseThre

Specifies the memory usage alarm threshold.

Supported

MeInfo

DiskPartitionUsageThre

Specifies the hard disk partition usage alarm threshold.

Supported

PRODUCT

WOLState

Specifies whether the wake on LAN function is enabled.

Supported

System boot option

Bios

StartOption

Specifies the first boot device.

Supported

Bios

StartOptionFlag

Specifies whether the boot setting takes effect permanently or just for one time only.

Supported

Bios

StartOptionFlagExt

Specifies whether the previous setting has taken effect when the effective mode is One time.

Supported

Alarm settings

SyslogConfig

EnableState

Specifies whether Syslog is enabled.

Supported

SyslogConfig

MsgIdentity

Identifies the Syslog host.

Supported

SyslogConfig

MsgSeverity

Specifies Syslog alarm severity level.

Supported

SyslogConfig

NetProtocol

Specifies the Syslog transmission protocol.

Supported

SyslogConfig

AuthType

Specifies the Syslog authentication mode.

Supported

SyslogItemCfg

EnableState

Specifies whether the Syslog server is enabled.

Supported

SyslogItemCfg

DestAddr

Specifies the Syslog server address.

Supported

SyslogItemCfg

DestPort

Specifies the Syslog server port number.

Supported

SyslogItemCfg

LogSrcMask

Specifies the Syslog log type.

Supported

TrapConfig

TrapEnable

Specifies whether Trap is enabled.

Supported

TrapConfig

TrapVersion

Specifies the Trap version.

Supported

TrapConfig

Trapv3Userid

Specifies the SNMPv3 user name.

Supported

TrapConfig

TrapMode

Specifies Trap mode.

Supported

TrapConfig

TrapIdentity

Identifies the Trap host.

Supported

TrapConfig

CommunityName

Specifies the Trap community name.

Not supported

Sensitive information is displayed in ciphertext in the configuration file.

TrapConfig

SendSeverity

Specifies the severity level for sending a Trap alarm.

Supported

TrapItemCfg

ItemEnable

Specifies whether the Trap server is enabled.

Supported

TrapItemCfg

DestIpAddr

Specifies the Trap server address.

Supported

TrapItemCfg

DestIpPort

Specifies the Trap server port number.

Supported

TrapItemCfg

Separator

Specifies the delimiter to be used in a message.

Supported

TrapItemCfg

Time

Specifies the message content (time).

Supported

TrapItemCfg

SensorName

Specifies the message content (sensor name).

Supported

TrapItemCfg

Severity

Specifies the message content (severity level).

Supported

TrapItemCfg

EventCode

Specifies the message content (event code).

Supported

TrapItemCfg

EventDesc

Specifies the message content (event description).

Supported

TrapItemCfg

ShowKeyWord

Specifies whether to display the keywords in a message.

Supported

TrapItemCfg

BobEnable

Specifies whether trap messages can be transferred through inband channels.

Supported

TrapItemCfg

BmaVethIpAddr

Specifies the IP address of the BMA veth port for transferring trap messages through the inband channels.

Supported

TrapItemCfg

BmaVethIpPort

Specifies the number of the BMA veth port for transferring trap messages through the inband channels.

Supported

SmtpConfig

SmtpEnable

Specifies whether SMTP is enabled.

Supported

SmtpConfig

SmtpServer

Specifies the SMTP address.

Supported

SmtpConfig

TlsSendMode

Specifies whether TLS is enabled.

Supported

SmtpConfig

AnonymousMode

Specifies whether anonymous login is enabled.

Supported

SmtpConfig

LoginName

Specifies the email sender name.

Supported

SmtpConfig

LoginPasswd

Specifies the email sender password.

Not supported

Sensitive information is displayed in ciphertext in the configuration file.

SmtpConfig

SenderName

Specifies the mailbox address of the sender.

Supported

SmtpConfig

TempletTopic

Specifies the email subject.

Supported

SmtpConfig

TempletIpaddr

Specifies whether the email subject contains the host name.

Supported

SmtpConfig

TempletBoardSn

Specifies whether the email subject contains the board serial number.

Supported

SmtpConfig

TempletAsset

Specifies whether the email subject contains the product asset tag.

Supported

SmtpConfig

SendSeverity

Specifies the severity levels of the alarms to be sent.

Supported

SmtpItemCfg

EmailName

Specifies the recipient address.

Supported

SmtpItemCfg

EmailDesc

Provides information about the alarm

Supported

SmtpItemCfg

ItemEnable

Specifies whether alarm email notifications are sent to the recipient.

Supported

Power control

ChassisPayload

PowerOffTimeoutEN

Specifies whether power-off timeout period is enabled.

Supported

ChassisPayload

PowerOffTimeout

Specifies the power-off timeout period.

Supported

ChassisPayload

PwrButtonLock

Specifies whether the power button on the server front panel is disabled.

Supported

ChassisPayload

PowerRestorePolicy

Specifies the power restore policy when the power supply is connected.

Supported

Power

PowerCapping

Enable

Specifies whether power capping is enabled.

Supported

PowerCapping

LimitValue

Specifies the power cap value.

Supported

PowerCapping

FailAction

Specifies whether to forcibly shut down the server if the power capping fails.

Supported

Energy saving settings

SysPower

ExpectedMode

Specifies the power supply working mode.

Supported

SysPower

ExpectedActive

Specifies the active power supply.

Supported

Remote control

Kvm

EncryptState

Specifies whether KVM encryption is enabled.

Supported

Vmm

EncryptState

Specifies whether VMM encryption is enabled.

Supported

Kvm

KeyboardMode

Specifies whether persistent connection of the virtual keyboard and mouse is enabled.

Supported

Kvm

KvmTimeout

Specifies the remote console timeout period.

Supported

Kvm

LocalKVMState

Specifies whether local KVM is enabled.

Supported

Video playback

Video

VideoSwitch

Specifies whether video recording is enabled.

Supported

Screenshot

Kvm

ScreenSwitch

Specifies whether last screenshot is enabled.

Supported

Black box

Diagnose

BlackBoxState

Specifies whether black box is enabled.

Supported

Serial port data

Diagnose

SolDataState

Specifies whether serial port data is enabled.

Supported

Others

HMMSSHNAT

State

Specifies whether NAT is enabled.

Supported

ExPortConfig

State

Specifies whether SSDP is enabled.

Supported

HMMSSHNAT

Port

Specifies the NAT port number.

Supported

Bios

BiosPrintFlag

Specifies the setting of the BIOS print switch.

Supported

Cooling

Mode

Specifies the speed adjustment mode of fans.

Not supported

The value is displayed in the configuration file.

Cooling

PowerMode

Specifies the power supply mode.

Supported

Cooling

Level

Specifies the fan speed level.

Not supported

The value is displayed in the configuration file.

Stateless

Enable

Specifies whether stateless computing is enabled.

Supported

Stateless

SysManagerID

Specifies the remote management ID. (stateless computing configuration)

Supported

Stateless

AutoPowerOn

Specifies whether to enable self-control power-on. (stateless computing configuration)

Supported

Stateless

BroadcastNetSegment

Specifies the broadcast network segment used for automatic discovery. (stateless computing configuration)

Supported

Stateless

BroadcastPort

Specifies the broadcast port number used for automatic discovery. (stateless computing configuration)

Supported

Stateless

SysManagerIP

Specifies the IP address of the server that performs power control. (stateless computing configuration)

Supported

Stateless

SysManagerPort

Specifies the port number of the server that performs power control. (stateless computing configuration)

Supported

USBMassStorage

UmsMaxUpdateSpace

Specifies the flag indicating that the component configuration or upgrade package is delivered to the NAND flash memory.

Supported

USBMassStorage

SpConfigFileReady

Specifies the mode for accessing the SP.

Supported

USBMassStorage

SPStartmode

Specifies the interval between the SP operation completion time and the OS reset time.

Supported

USBMassStorage

SysRestartDelay

Specifies the OS restart delay.

Supported

SmBios

Version

Specifies the value of the Version parameter in SMBIOS.

Supported

SmBios

SKUNumber

Specifies the value of the SKUNumber parameter in SMBIOS.

Supported

SmBios

Family

Specifies the value of the Family parameter in SMBIOS.

Supported

Table 9-2 BIOS parameters

Parameter

Description

ProcessorHyperThreadingDisable

Specifies whether processor hyper-threading is enabled.

ProcessorFlexibleRatioOverrideEnable

Specifies whether the feature of setting the CPU frequency upper limit is enabled. This feature is disabled by default.

ProcessorFlexibleRatio

Specifies the CPU frequency upper limit. By default, it is the nominal CPU frequency.

MonitorMwaitEnable

Specifies whether Monitor/Mwait is enabled.

ProcessorVmxEnable

Specifies whether CPU virtualization is enabled.

ProcessorLtsxEnable

Specifies whether Intel TXT is enabled.

MlcStreamerPrefetcherEnable

Specifies whether hardware prefetcher is enabled. Before processing instructions or data, the CPU prefetches these instructions or data and saves them to the L2 cache. This reduces memory read time, eliminates potential bottlenecks, and therefore improves system performance.

MlcSpatialPrefetcherEnable

Specifies whether adjacent cache prefetcher is enabled. This feature allows prefetch of the data adjacent to the data to be read. This improves read speed significantly.

DCUStreamerPrefetcherEnable

Specifies whether DCU streamer prefetcher is enabled. This function allows CPU data to be prefetched, which reduces data read time.

DCUIPPrefetcherEnable

Specifies whether DCU IP prefetcher is enabled. This function enables the system to check historical records for the data that must be prefetched, which reduces data read time.

CustomPowerPolicy

Menu for selecting the energy-saving mode. It does not support customization.

PowerSaving

Indicates a Huawei-customized parameter for Dynamic Energy Management Technology (DEMT), integrates uniBIOS frequency adjustment algorithms developed by Huawei, and improves energy efficiency test results. This parameter is valid only for specific OSs

ProcessorEistEnable

Specifies whether Enhanced Intel SpeedStep® Technology (EIST) is enabled. EIST enables CPU frequency to be dynamically adjusted based on workloads, reducing heat dissipation.

TurboMode

Specifies whether CPU Turbo mode is enabled.

PStateDomain

PStateDomain switch. PStateDomain adjusts frequencies by core or package.

ProcessorCcxEnable

CPU C-state control menu, which controls the power consumption of CPUs in idle state.

TStateEnable

CPU T-state switch. This function is not available because it limits the CPU frequency.

PackageCState

Package C state setting.

C3Enable

CPU C3 state setting switch.

C6Enable

CPU C6 state setting switch.

ProcessorC1eEnable

CPU C1e state setting switch.

OSCx

ACPI C2/C3 adjustment

QpiLinkSpeed

QPI LINK Speed

ClusterOnDieEn

Memory Snoop mode ClusterOnDie setting switch

EarlySnoopEn

Memory Snoop mode EarlySnoop and HomeSnoop setting switch

DdrFreqLimit

Memory frequency setting switch.

RankMargin

Rank Margin Tool switch.

rmtPatternLength

RMT Pattern Length, which is set when Rank Margin Tool is enabled.

MemTestOnFastBoot

Memory test switch set for fast boot.

ADREn

Memory ADR switch

CustomRefreshRateEn

Memory refresh rate switch.

CustomRefreshRate

Specifies the memory refresh rate.

refreshMode

Specifies the memory refresh mode. 1 indicates 2x memory self-refresh, and 0 indicates that 2x memory self-refresh is not supported. If this parameter is set to 1, the memory refresh rate will be doubled when the memory DIMM exceeds 85ºC.

mcODTOverride

Memory mc on die termination (ODT) setting. ODT(on die termination) is a mechanism that allows the DRAM controller to dynamically control the termination resistance value of DQ/DQS/DM pins on DRAM devices in a variety of ways. The value can be 50 ohms or 100 ohms.

NumaEn

Non Uniform Memory Access (NUMA) is a distributed memory access mode. It allows reasonable memory allocation among multiple nodes and the processor to simultaneously access different memory addresses.

IsocEn

Specifies whether to enable the isochronous flow-control mode, which ensures the quality of traffic to/from PCH and impacts the memory performance because some bandwidths are reserved for DMI.

RASMode

Specifies the memory RAS mode. It can be independent mode, mirrored mode, or Lockstep mode.

enableSparing

Rank Sparing setting switch

multiSparingRanks

Haswell CPU supports multiple spare ranks. You can set the number of spare ranks for a channel.

spareErrTh

Memory correctable error threshold. When the number of correctable errors reaches this threshold, an SMI will be triggered and measures will be taken based on the RAS feature configured.

PatrolScrub

Controls the memory patrol scrub feature. The memory engine checks the memory at a certain speed and correct the correctable errors found, to prevent errors from being accumulated to uncorrectable errors.

PatrolScrubDuration

Specifies the memory patrol duration in hours.

DemandScrubMode

Controls the Demand Scrub feature. When HA reads memory data, it corrects errors found and writes correct data to the memory.

DeviceTaggingMode

Controls the Device Tagging feature. This feature allows an SMI to be triggered when the number of errors occurred on a memory chip exceeds the threshold. During the SMI processing, a parity chip can be used to replace the faulty chip.

thermalthrottlingsupport

Specifies the memory temperature adjustment mode.

Closed Loop Thermal Throttling (CLTT) applies to DIMMs with temperature sensors. It allows dynamic memory adjustment based on the sensor temperature.

Open Loop Thermal Throttling (OLTT) applies to DIMMs without temperature sensor. It allows static memory adjustment based on configuration.

PcieAcpiHotPlugEnable

Specifies whether to enable IIO PCI-E Hotplug.

EnableAzaliaVCpOptimizationste

Specifies whether to enable azalia_on_vcp.

PCIeSRIOVSupport

Specifies whether to enable PCIe virtualization function.

VTdSupport

Specifies whether to enable Intel VT for Directed I/O (VT-d).

InterruptRemap

Specifies whether to enable Interrupt Remapping, which is related to VT-d.

CoherencySupport

Specifies whether to enable Coherency Support, which is related to VT-d.

IsochCoherencySupport

Specifies whether to enable Coherency Support (Isoch), which is related to VT-d.

IdeController

Specifies whether to enable SATA controller.

SataCnfigure

Specifies the SATA controller mode.

PchsSata

Specifies whether to enable sSATA controller.

sSataInterfaceMode

Specifies the sSATA controller mode.

XHCIMode

Specifies the USB 3.0 controller switch.

CREnable

Serial port redirection switch.

CRTerminalType

Font type selection switch for serial port redirection.

CRBaudRate

Baud Rate selection switch for serial port redirection.

CRInfoWaitTime

Initialization information display time for serial port redirection.

CRAfterPost

Specifies whether serial port redirection takes effect after BIOS POST.

PXE1setting

LOM 1 PXE switch

PXE2setting

LOM 2 PXE switch

WheaSupport

Specifies whether to enable WHEA for fault diagnosis.

WheaEinjType

Specifies whether to enable WHEA error injection for fault diagnosis.

SystemErrorEn

Specifies whether to enable fault diagnosis.

FDM

Specifies whether to enable reporting of fault diagnosis to the BMC.

PoisonEn

Poison bit switch.

EMcaLogEn

EMCA log (ELOG) switch. The BIOS creates ELOG entries, which record error information in detail for the OS/VMM to predict faults. The log is stored in the reserved memory provided by the BIOS and accessed through the Entry address. There is also a WHEA log corresponding to ELOG, and the structure of the WHEA log is defined by ACPI specifications.

EMcaCSmiEn

CMCI-to-SMI signal switch.

If it is disabled, only CMCI will be triggered when correctable errors are found on the memory. An SMI will be triggered only when the number of errors reaches the threshold.

If it is enabled, each correctable error will trigger an SMI, which is processed by the BIOS. At the end of the SMI processing function, the BIOS decides whether to send an MCE signal to the OS. This helps to collect more useful information.

PowerStateRestoreOnACLoss

Specifies the power control policy for the operating system when the AC is powered on.

  • ON: Automatic power-on
  • OFF: Remain power-off
  • Last State: Restore the last state

BmcWdtEnable

Specifies whether to enable the POST watch dog.

BmcWdtTimeout

Specifies the timeout period of the POST watch dog.

BmcWdtAction

Specifies the POST watch dog actions.

OSWdtEnable

Specifies whether to enable the OS watch dog.

OSWdtTimeout

Specifies the timeout period of the OS watch dog.

OSWdtAction

Specifies the OS watch dog actions.

SysDbgLevel

BIOS debugging switch

serialDebugMsgLvl

BISO debugging print level.

Pci64BitResourceAllocation

If this function is enabled, the PCI MMIO address space is greater than 4 GB.

ClkGenSpreadSpectrum

Spread spectrum switch.

WakeOnPME

Wake On LAN switch.

NICTrunk

Before OS starts, the DisableNic2ndhandle function will be called to disable the second optical port of 82599. This function is not available at present.

Language

Specifies the language used.

ComBaseOutput

Serial port IO base settings.

OemMemTurbo

Memory overclock switch.

SoftRaidModeSelect

SoftRAID selection switch.

BootType

Specifies the boot type, which can be Legacy, UEFI, or DUAL.

QuickBoot

Quick Boot settings. If it is disabled, a memory test will be performed after the first screen after each start.

QuietBoot

Specifies whether to display boot information before the BIOS logo appears.

PXEOnly

Specifies whether to limit the server to boot from PXE only and skip other boot options (such as a hard disk and CD-ROM).

VideoSelected

Onboard video card or external video card

NoBootDevCtr

Specifies whether the board is automatically restarted when no boot device is available.

BootTypeOrder[0]

Specifies the boot sequence.

BootTypeOrder[1]

Specifies the boot sequence.

BootTypeOrder[2]

Specifies the boot sequence.

BootTypeOrder[3]

Specifies the boot sequence.

Table 9-3 RAID controller card parameters

Type

Export Parameter

Export Subparameter

Description

Imported by Configuration File

Storage

RaidController

Type

Specifies the controller type.

Not supported

The value is displayed in the configuration file.

RaidController

CopybackEnabled

Specifies the copyback function status of the RAID controller card.

Supported

RaidController

SMARTerCopybackEnabled

Specifies whether to automatically perform copyback when the RAID controller card detects a physical disk SMART error.

Supported

RaidController

JBODEnabled

Specifies the JBOD function status of the RAID controller card.

Supported

Translation
Download
Updated: 2019-02-28

Document ID: EDOC1100019360

Views: 76546

Downloads: 384

Average rating: