Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Setting the Server Reset Mode (frucontrol)

Setting the Server Reset Mode (frucontrol)

Function

The frucontrol command is used to specify how the server is reset.

Format

ipmcset [-t fru0] -d frucontrol -v <option>

Parameters

Parameter Description Value
option Specifies the reset mode.
  • 0: Forcibly restarts the server.
  • 2: Forcibly power cycle (power off and power on) the server.

Usage Guidelines

This command is invalid to a server in power-off state.

Example

# Forcibly reset the server.

iBMC:/->ipmcset -d frucontrol -v 0
WARNING: The operation may have many adverse effects.
Do you want to continue?[Y/N]:y
FRU control fru0 (forced system reset) successfully.

# Forcibly power cycle the server.

iBMC:/->ipmcset -d frucontrol -v 2
WARNING: The operation may have many adverse effects.
Do you want to continue?[Y/N]:y
FRU control fru0 (forced power cycle) successfully.