OSN 500 550 580 V100R008C50 Alarms and Performance Events Reference 02

Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
NO_BD_PARA

NO_BD_PARA

Description

The NO_BD_PARR alarm indicates absence of the board parameter table.

Attribute

Alarm Severity Alarm Type

Critical

Equipment alarm

Parameters

None

Impact on the System

The parameter table file of the board is lost, which may influence the services of users.

Possible Causes

  • The correct parameter table is not loaded before delivery.

  • The incorrect parameter table file is loaded on site, which overlaps the original file.

  • The parameter table file is abnormally lost in the running process.

Procedure

  1. Perform warm reset on the faulty board through the NMS. For details, see Resetting Boards in the Supporting Tarks.
  2. If the alarm persists, reset (cold) or reseat the faulty board. For details, see Resetting Boards in the Supporting Tarks.

    Cold resetting or replacing a board will interrupt services. The operation is risky.

  3. If the alarm persists, replace the faulty board. For details, see Parts Replacement.

Related Information

None