Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
R_LOC

R_LOC

Description

The R_LOC alarm indicates loss of clock in the signals received by the line board at the optical interface.

Attribute

Alarm Severity Alarm Type

Critical

Equipment alarm

Parameters

When you view an alarm on the network management system, select the alarm. In the Alarm Details field display the related parameters of the alarm. The alarm parameters are in the following format: Alarm Parameters (hex): parameter1 parameter2...parameterN. For details about each parameter, refer to the following table.

Name Meaning

Parameter 1

Indicates the actual number of the optical interface on a board where the alarm occurs.

For example, 0x01 indicates that the alarm is reported from optical interface 1 of the board.

Parameter 2, parameter 3

Indicates the actual number of the optical interface on a board where the alarm occurs.

For example, 0x01 indicates that the alarm is reported from optical interface 1 of the board.

Impact on the System

When the R_LOC alarm occurs, the clock in the signals received by the line board at the optical interface is lost. As a result, the services at the optical interface are unavailable. If the automatic MSP switching or the path protection switching is configured, the alarm will trigger the protection switching. If the optical interface that reports the R_LOC alarm is the current synchronization clock source for the NE, the synchronization clock source switching will occur.

When the R_LOC alarm occurs, the board reports the MS_RDI alarm to the opposite station.

Possible Causes

Possible causes of the R_LOC alarm are as follows:

  • The clock in the received line signals is lost.

Procedure

  1. If receive part of the local line board is faulty, replace the board.

Related Information

None.