Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
BD_STATUS

BD_STATUS

Description

The BD_STATUS alarm indicates that a board for which the logical board has been created cannot be detected or is offline.

Attribute

Alarm Severity Alarm Type

Major

Equipment alarm

Parameters

None.

Impact on the System

The functions of the board are unavailable.

Possible Causes

Possible causes of this alarm are as follows:

  • The board is not installed or is loosely installed.
  • The RAM is faulty.
  • The board is faulty.

Procedure

  1. Check whether the board is correctly installed in the slot.

    If... Then...
    The board is not installed Install the board correctly. Then, check whether the alarm is cleared. If the alarm persists, go to the next step.
    If the board is loosely installed Reinstall the board correctly. Then, check whether the alarm is cleared. If the alarm persists, go to the next step.
    If the board is correctly installed Go to the next step.

  2. Check whether the RAM on the equipment is faulty.

    If... Then...
    The RAM is faulty Replace the RAM. Then, check whether the alarm is cleared. If the alarm persists, go to the next step.
    The RAM is functioning properly Go to the next step.

  3. Check whether the board is faulty.

    If... Then...
    The board is faulty Perform a cold reset on the board, or replace the board.
    The board is functioning properly Contact Huawei technical support engineers to handle the alarm.