Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Alarm List I

Alarm List I

This section used a table to list the alarms starting with I.

Name Description Severity Applicable Equipment
IGSP_ENTRIES_EXC Indicates that the number of IGMP Snooping multicast table entries exceeds its upper threshold. Minor OptiX OSN 550/500/580
IMA_GROUP_LE_DOWN Indicates a failure in the local IMA group. Major OptiX OSN 550/500
IMA_GROUP_RE_DOWN Indicates a failure in the remote IMA group. Major OptiX OSN 550/500
IMA_TXCLK_MISMATCH Indicates that the transmit clock modes at both ends of the IMA group are different. Minor OptiX OSN 550/500
IN_PWR_ABN Indicates that the input optical power of the line board laser crosses the lower or upper threshold. Major OptiX OSN 550/500/580
IN_PWR_HIGH Indicates that the actual input optical power is higher than the upper threshold of the input power reference value. Critical OptiX OSN 550/500/580
IN_PWR_LOW Indicates that the actual input optical power is lower than the lower threshold of the input power reference value. Critical OptiX OSN 550/500/580
INSUFFCNT_FLSH_SPACE The file system space on the flash is insufficient. Critical OptiX OSN 550/500/580
INSUFFCNT_MEM_SPACE The file system space in the memory is insufficient. Critical OptiX OSN 550/500/580
INTEMP_SENSOR_FAIL Indicates that the inlet temperature sensor fails. Major OptiX OSN 550/500