Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
CES_LOSPKT_EXC

CES_LOSPKT_EXC

Description

The CES_LOSPKT_EXC alarm indicates that the average number of lost packets exceeds the upper threshold value within one second in a period. If the average number of lost packets in a second is smaller than the lower threshold value in another period, this alarm is cleared automatically.

Attribute

Alarm Severity Alarm Type

Major

Communication alarm

Parameters

None.

Impact on the System

When the packet loss rate exceeds the threshold value, all "1"s are inserted in the downstream. As a result, services are interrupted.

Possible Causes

Possible causes of the CES_LOSPKT_EXC alarm are as follows:

  • The parameter settings for the NEs at both ends of the CES service are inconsistent.
  • The bandwidth configured for the tunnel or PW is so low that the link is congested.
  • The link signals deteriorate or are interrupted due to a fault in cables, optical fibers, or optical modules.

Procedure

  1. Check whether the parameter settings (for example, 64K Timeslot) are consistent on the NEs at the local and opposite ends of the CES service.
  2. If the parameters settings are inconsistent at both ends, change the parameters settings to be the same and then check whether the alarm is cleared. If the alarm persists, go to 3.
  3. Check whether the bandwidth configured for the tunnel or PW which carries the CES service is too low.
  4. If the bandwidth configured for the tunnel or PW which carries the CES service is too low, allocate the tunnel or PW higher bandwidth. Then, check whether the alarm is cleared. If the alarm persists, go to 5.
  5. Check whether cables or optical fibers are incorrectly connected to the ports and whether the ports are dirty.
  6. If the cables or optical fibers are incorrectly connected, reconnect the cables or optical fibers.
  7. Check whether the alarm is cleared. If the alarm persists, replace the cables, optical cables, or optical modules/boards.
  8. Check whether the alarm is cleared. If the alarm persists, contact Huawei technical support engineers to handle the alarm.