Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
OTUk_BDI

OTUk_BDI

Description

The OTUk_BDI alarm indicates that an NE receives an OTUk backward defect indication (BDI). When detecting a signal fail (SF) condition using the section monitoring (SM) field, an NE sends a BDI signal (all bits of the BDI byte are "1") to its upstream NE. Upon receiving the BDI signal, the upstream NE reports an OTUk_BDI alarm.

k indicates the level of rate, its value is 2 or 3.

Attribute

Alarm Severity Alarm Type

Warning

Communication alarm

Parameters

None

Impact on the System

The signal quality of services carried on the optical port that reports an OTUk_BDI alarm deteriorates.

Possible Causes

  • Cause 1: Signals received contain an OTUk_BDI signal.

    The following figure shows details. NE 1 and NE 2 interconnect with each other, and traffic flows from NE 1 to NE 2. When detecting an OTUk_BDI signal in signals received, the board of NE 1 reports an OTUk_BDI alarm.



  • Cause 2: An board on a downstream NE of the NE that reports an OTUk_BDI alarm reported an OTUk_AIS, OTUk_LOF, OTUk_LOM, OTUk_SSF, or OTUk_TIM alarm.

    The following figure shows details. Traffic flows from NE 1 to NE k. When an board on a downstream NE of NE 1 detects an OTUk_AIS, OTUk_LOF, OTUk_LOM, OTUk_SSF, or OTUk_TIM alarm signal, the downstream NE sends a BDI signal to NE 1. When detecting the BDI signal, the board of NE 1 reports an OTUk_BDI alarm.



Procedure

  1. Cause 1: Signals received contain an OTUk_BDI signal.
    1. Check whether signals received contain an OTUk_BDI signal. If the signals contain an OTUk_BDI signal, rectify the fault in the signals.
    2. Check whether the alarm is cleared. If the alarm persists, go to 2.
  2. Cause 2: An board on a downstream NE of the NE that reports an OTUk_BDI alarm reported an OTUk_AIS, OTUk_LOF, OTUk_LOM, OTUk_SSF, or OTUk_TIM alarm.
    1. On the NMS, check for an OTUk_LOF, OTUk_LOM, OTUk_AIS, OTUk_TIM, or OTUk_SSF alarm on each downstream board. If a downstream board reports any such alarms, clear these alarms.
    2. Check whether the OTUk_BDI alarm is cleared. If the alarm persists, contact Huawei engineers to handle the alarm.