OSN 500 550 580 V100R008C50 Alarms and Performance Events Reference 02

Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
HPSES

HPSES

Performance Event Meaning

The HPSES event indicates the higher-order path severely errored second.

Performance Event Attributes

Performance Event ID Performance Event Type

0x32

SDH performance event

Impact on the System

If bit errors occur in the services, identify the causes and rectify the fault immediately. Otherwise, alarms will be generated and the signal transmission quality will be affected. If bit errors exceed the B3 bit error threshold-crossing threshold and degrade threshold, the B3_EXC and B3_SD alarms will be generated.

Possible Causes

The HPSES event occurs when one of the following requirements is met: 1. Not less than 30% bit errors are detected in one second. 2. At least one severely disturbed period (SDP) occurs. The SDP indicates that the BER of all the consecutive blocks is not lower than 10-2 or the LOS, LOF and MS_AIS alarms occur in a period of at least four consecutive blocks or 1 ms (the longer one is selected), or the AU_AIS, AU_LOP, HP_UNEQ, and HP_TIM alarms are detected on the path.

External causes:

  • The fiber performance is degraded, and the fiber has high attenuation.

  • The fiber connector is dirty or incorrect.
  • The equipment is poorly grounded.
  • A severe interference source is present near the equipment.
  • The working temperature is high or low, and the opposite equipment cannot tolerate such temperature.

Equipment problems:

  • The signal attenuation on the receive side of the line board is excessive, the transmit circuit at the opposite end is faulty, or the receive circuit at the local end is faulty.

  • The synchronization performance of the clock is poor.
  • The cross-connect unit and the line board poorly match.
  • The board becomes faulty, or the performance of the board is degraded.

Relevant Alarms

Alarm Name Correlation

B3_EXC

B3 bit errors crossing the threshold

B3_SD

Signals degraded (B3)

R_LOS

The signal on the receiver line side is lost.

R_LOF

The out-of-frame fault occurs on the receiver line side.

MS_AIS

Multiplex section alarm indication

AU_AIS

AU alarm indication

AU_LOP

AU pointer loss

HP_UNEQ

Higher-order path unequipped

HP_TIM

Higher-order path trace identifier mismatch

Procedure

  1. See HPES.

Reference

None.