Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
A_LOC

A_LOC

Description

The A_LOC alarm indicates that the upstream bus clock at the electrical port of a tributary board is lost.

Attribute

Alarm Severity Alarm Type

Major

Equipment alarm

Parameters

None.

Impact on the System

Services on the board where the alarm is generated are interrupted.

Possible Causes

Possible causes of this alarm are as follows:

  • The interconnected PDH equipment is incorrectly configured or is faulty.
  • The service type is incorrectly configured.
  • The service cross-connections are incorrectly configured.
  • The board hardware is faulty.
  • The cross-connect and timing units are faulty.

Procedure

  1. Check whether the interconnected PDH equipment is incorrectly configured or is faulty.

    If... Then...
    The interconnected PDH equipment is incorrectly configured Configure the PDH equipment correctly. Then, check whether the alarm is cleared. If the alarm persists, go to the next step.
    The interconnected PDH equipment is faulty Troubleshoot the PDH equipment. Then, check whether the alarm is cleared. If the alarm persists, go to the next step.
    The interconnected PDH equipment is operating properly Go to the next step.

  2. Check whether the service type is incorrectly configured at the local end.

    If... Then...
    The service type is incorrectly configured Configure the service type correctly. Then, check whether the alarm is cleared. If the alarm persists, go to the next step.
    The service type is correctly configured Go to the next step.

  3. Check whether the service cross-connections are incorrectly configured at the local end.

    If... Then...
    The service cross-connections are incorrectly configured Configure the service cross-connection correctly. Then, check whether the alarm is cleared. If the alarm persists, go to the next step.
    The service cross-connections are correctly configured Go to the next step.

  4. Check whether the service cross-connections are incorrectly configured at the opposite end.

    If... Then...
    The service cross-connections are incorrectly configured Configure the service cross-connection correctly. Then, check whether the alarm is cleared. If the alarm persists, go to the next step.
    The service cross-connections are correctly configured Go to the next step.

  5. Check whether the tributary board is faulty.

    If... Then...
    The tributary board is faulty Replace the faulty board. Then, check whether the alarm is cleared. If the alarm persists, go to the next step.
    The tributary board is functioning properly Go to the next step.

  6. Check whether the cross-connect and timing units are faulty.

    If... Then...
    The cross-connect and timing units are faulty Replace the system control, cross-connect, and timing board.
    The cross-connect and timing units are functioning properly Contact Huawei technical support engineers to handle the alarm.