OSN 500 550 580 V100R008C50 Alarms and Performance Events Reference 02

Rate and give feedback :
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
About This Document

About This Document

Related Versions

The following table lists the product versions related to this document.

Product Name Version
OptiX OSN 500 V100R008C50
OptiX OSN 550 V100R008C50
OptiX OSN 580 V100R008C50
iManager U2000 V200R018C50

Intended Audience

Based on various services of the OptiX OSN equipment, this document describes the troubleshooting process, which involves background knowledge, information collection, general processing flow, common troubleshooting methods, and case study.

This document provides guides to get the information about how to handle the troubleshooting.

This document is intended for:

  • Field maintenance engineer
  • System maintenance engineer

Symbol Conventions

The symbols that may be found in this document are defined as follows.

Symbol

Description

DANGER Indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury.

WARNING Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury.

CAUTION Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury.

NOTICE Indicates a potentially hazardous situation which, if not avoided, could result in equipment damage, data loss, performance deterioration, or unanticipated results. NOTICE is used to address practices not related to personal injury.

Provides a tip that may help you solve a problem or save time.

Provides additional information to emphasize or supplement important points in the main text.

GUI Conventions

The GUI conventions that may be found in this document are defined as follows.

Convention

Description

Boldface

Buttons, menus, parameters, tabs, window, and dialog titles are in boldface. For example, click OK.

>

Multi-level menus are in boldface and separated by the ">" signs. For example, choose File > Create > Folder.

Change History

Updates between document issues are cumulative. Therefore, the latest document issue contains all updates made to previous issues.

Updates in Issue 02 (2019-01-03) Based on Product Version V100R008C50

This document is the second issue for product version V100R008C50. Compared with Issue 01, this issue includes the following updates:

  • OSN 550/580: in "Alarm Clearing", updated information of DB_UNSAVE alarm.
  • OSN 550/580: In "Alarm Clearing", added information about DELAY_ADAPT_INVALID.
  • OSN 500/550: in "CES Performance Event List", added information of CES_TX_PKTS performance event.

Updates in Issue 01 (2018-04-30) Based on Product Version V100R008C50

This document is the first issue for product version V100R008C50. Compared with V100R008C30, V100R008C50 includes the following updates:

  • In "Alarm Clearing", added information about the following alarms:
    • OSN 500: MAC_EXT_EXC.
    • OSN 550: AD_CHECK_FAIL, MUT_LOS, MAC_EXT_EXC, NO_BD_PARA, NO_ELABEL, OA_LOW_GAIN, PUM_BCM_ALM, PUM_TEM_ALM, PUMP_COOL_EXC, SUM_INPWR_HI, SUM_INPWR_LOW.
    • OSN 580: PING_ARP_MISMATCH, PING_LOS.
    • OSN 550/580: C3794_SLOTNUM_ERR, C3794_RDI, C3794_AIS, RELAY_LOF, DB_UNSAVE.
  • In "Alarm Clearing", updated information about the following alarms:
    • OSN 500/550: MPLS_TUNNEL_UNEXPMEP, MPLS_TUNNEL_UNEXPMEG, MPLS_PW_UNEXPMEP, MPLS_PW_UNEXPMEG, MPLS_PW_MISMATCH, MPLS_PW_MISMERGE, MPLS_TUNNEL_MISMATCH, MPLS_TUNNEL_MISMERGE.
    • OSN 550: BUS_ERR.
    • OSN 580: HARD_ERR.
    • OSN 550/580: LOF_64K, HARD_BAD.
  • In "Performance Event Reference", added information about the following performance events:
    • OSN 550: BCV, CCV, EDTMP, SUMIOP, SUMOOP, WCV, XCSTMP.
    • OSN 550/580: C3794_LCV_SDH, C3794_LES_SDH, C3794_LSES_SDH.
    • OSN 500/550: Added the performance events PKT64, PKT65, PKT128, PKT256, PKT512, and PKT1024 in section of "Statistics of RMON Extended Performance (packet)".
Translation
Download
Updated: 2019-01-21

Document ID: EDOC1100020975

Views: 75598

Downloads: 138

Average rating:
This Document Applies to these Products
Related Documents
Related Version
Share
Previous Next