No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

OSN 500 550 580 V100R008C50 Alarms and Performance Events Reference 02

Rate and give feedback :
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
INSUFFCNT_FLSH_SPACE

INSUFFCNT_FLSH_SPACE

Description

The INSUFFCNT_FLSH_SPACE alarm indicates that the flash file space is insufficient.

  • This alarm is reported when the flash space usage exceeds 95% for OSN 500 or OSN 550.
  • This alarm is reported when the flash space usage exceeds 85% for OSN 580.

Attribute

Alarm Severity Alarm Type
Critical Processing failure alarm

Parameters

When you view an alarm on the network management system, select the alarm. In the Alarm Details field display the related parameters of the alarm. The alarm parameters are in the following format: Alarm Parameters (hex): parameter1 parameter2...parameterN. For details about each parameter, refer to the following table.

Name Meaning
Parameter 1 Indicates the resource type.
  • 0x00: ofs1
  • 0x01: ofs2
Parameter 2 Indicates that the current flash space utilization.
Parameters 3 to 5 These parameters are reserved. Their values are always 0xff.

Impact on the System

File storage to the flash space fails.

Possible Causes

The file system space on the flash is insufficient.

Procedure

  1. Check the alarm on the NMS for the specific alarmed flash space according to the alarm parameters.
  2. Query the files stored in the alarmed flash space and check for any oversized files or extra files.
  3. Delete oversized and extra files, if any.
  4. Check whether the alarm clears. If the alarm persists, contact Huawei engineers to handle the alarm.

Related Information

None.

Translation
Download
Updated: 2019-01-21

Document ID: EDOC1100020975

Views: 75096

Downloads: 138

Average rating:
This Document Applies to these Products
Related Documents
Related Version