Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
DDN_RMFA

DDN_RMFA

Description

The DDN_RMFA is a remote alarm of the framed E1 multiframe on the DDN side of a board. If the E1 signals received on the DDN side occur in Z (Z is from two through five) consecutive CAS multiframe cycles, the DDN_RMFA alarm is reported when all the CAS multiframe remote alarm bits of the input signals are set to 1.

Attribute

Alarm Severity Alarm Type

Minor

Communication alarm

Parameters

None

Impact on the System

When the DDN_RMFA alarm occurs, the services at the local station are not affected. This alarm just shows that the DDN_LMFA alarm is received at the opposite station.

Possible Causes

The possible cause of the DDN_RMFA alarm is as follows:

The DDN_LMFA alarm is received at the opposite end.

Procedure

  1. After you clear the DDN_LMFA alarm received at the opposite end, the DDN_RMFA alarm is automatically cleared.