OSN 500 550 580 V100R008C50 Alarms and Performance Events Reference 02

Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
KMC_KEY_SYNC_FAIL

KMC_KEY_SYNC_FAIL

Description

The KMC_KEY_SYNC_FAIL alarm indicates a KMC key synchronization failure. (KMC is short for key management center.)

Attribute

Alarm Severity Alarm Type
Critical Communication alarm

Parameters

None

Impact on the System

The database cannot be backed up, KMC cannot be enabled or disabled, and KMC keys cannot be configured.

Possible Causes

  • Cause 1: The database on the alarmed NE is abnormal.
  • Cause 2: The database backup fails on the alarmed NE.

Procedure

  1. Restore NE data from the latest backup database.
  2. If NE data restoration fails, contact Huawei engineers to handle the alarm.

Related Information

None