Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
MASTER_SLAVE_MISMATCH

MASTER_SLAVE_MISMATCH

Description

The MASTER_SLAVE_MISMATCH is an alarm indicating that the logical types of the master and slave cross-connect boards are mismatched.

Attribute

Alarm Severity Alarm Type

Minor

Equipment alarm

Parameters

When you view an alarm on the network management system, select the alarm. In the Alarm Details field display the related parameters of the alarm. The alarm parameters are in the following format: Alarm Parameters (hex): parameter1 parameter2...parameterN. For details about each parameter, refer to the following table.

Name Meaning

Parameter 1

Indicates the alarm type:

0x01: indicates the logical types of the master and slave cross-connect boards are mismatched.

Parameter 2, Parameter 3

Indicates the cross-connect board slot number.

The value of this parameter 2 is always 0x53, and the value of this parameter is always 0x54.

Parameter 4

The value of this parameter is always 0x01. Indicates the logical types of the master and slave cross-connect boards are mismatched.

Impact on the System

None

Possible Causes

The possible cause of the MASTER_SLAVE_MISMATCH alarm is as follows:

Cause: The logical types of the master and slave cross-connect boards are mismatched.

Procedure

  1. Modify the configuration of the master and slave cross-connect boards on the NE and ensure the logical types of the master and slave cross-connect boards are same.
  2. Then, check whether the alarm is cleared. If the alarm persists, contact Huawei technical support engineers to handle the alarm.

Related Information