No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

OSN 500 550 580 V100R008C50 Alarms and Performance Events Reference 02

Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
MPLS_TUNNEL_OAMFAIL

MPLS_TUNNEL_OAMFAIL

Description

The MPLS_TUNNEL_OAMFAIL alarm indicates that the source and sink nodes of a tunnel fail to negotiate on the OAM protocol.

Attribute

Alarm Severity Alarm Type

Minor

Communication alarm

Parameters

None.

Impact on the System

MPLS APS switching is triggered and services are switched to the protection tunnel.

Possible Causes

Possible causes of the MPLS_TUNNEL_OAMFAIL alarm are as follows:

  • The OAM function is enabled only on either the source or the sink node of the tunnel.
  • The tunnel has been interrupted before the OAM function is enabled.

Procedure

  1. On the U2000, check whether the OAM function is enabled on NEs at both ends of the tunnel. Enable the OAM function if it is not enabled at either end.
  2. If the alarm persists, check whether the sink node of the alarmed tunnel reports the HARD_BAD, ETH_LOS, or R_LOS alarm.
    If... Then...

    the alarm is reported

    Exclude the alarms HARD_BAD, ETH_LOS, and R_LOS.

    the alarm is not reported

    Go to the next step.
  3. Clear the alarm. After the OAM protocol negotiation is successful, the MPLS_TUNNEL_OAMFAIL alarm clears.

Related Information

None.

Translation
Download
Updated: 2019-01-21

Document ID: EDOC1100020975

Views: 75855

Downloads: 138

Average rating:
This Document Applies to these Products
Related Documents
Related Version
Share
Previous Next