Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
PUM_TEM_ALM

PUM_TEM_ALM

Description

The PUM_TEM_ALM alarm indicates that the working temperature of the pump laser exceeds the threshold. This alarm occurs when the operating temperature of the pump laser on the optical amplifier unit crosses the threshold.

Attribute

Alarm Severity Alarm Type

Major

Equipment alarm

Parameters

Name Meaning

Parameter 1 and 2

Indicates the optical port where the alarm is generated.

Parameter 3

Indicates the threshold crossing type. For example, 0x01 indicates the upper threshold is crossed and 0x02 indicates the lower threshold is crossed.

Impact on the System

The pump laser may be aged. Report of this alarm has no impact on the services. If no measure is taken, however, the output optical power of the board is affected in a period of time. This affects the services.

Possible Causes

  • The ambient temperature is excessively high or excessively low.

  • The cooling system of the pump laser is damaged.

  • The pump laser has excessive current.

Procedure

  1. Check whether the ambient temperature is normal. If not, improve it.
  2. If the alarm persists, perform a warm reset on the faulty board through the NMS.
  3. If the alarm persists, you can reseat the faulty board if it does not affect services.
  4. If the alarm persists, replace the faulty board.

Related Information

None