Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
NULL_SEND

NULL_SEND

Description

NULL signals (with payload being "0"s) being sent out. When the NULL mapping status of the board is enabled, the NULL_SEND alarm is generated, indicating that the NULL signals are being sent out.

Attribute

Alarm Severity Alarm Type

Warning

Equipment alarm

Parameters

None

Impact on the System

When this alarm is generated, the board that reports the alarm is sending out NULL signals and the peer station will receive the NULL signals, interrupting services.

Possible Causes

The NULL Mapping Status parameter of the board is set to Enabled.

Procedure

  1. Check the NULL mapping status of the board that reports the alarm. If the NULL mapping status is enabled, change the value from Enabled to Disabled.

    NOTE:

    If the NULL mapping status needs to be enabled in the actual situation, suppress the alarm and then disable the NULL mapping status. After that, configure the NULL_SEND alarm to be monitored.

Related Information