Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
CES_APS_MANUAL_STOP

CES_APS_MANUAL_STOP

Description

The CES_APS_MANUAL_STOP alarm indicates that the packet linear MSP protocol is stopped manually.

Attribute

Alarm Severity Alarm Type

Minor

Communication alarm

Parameters

None

Impact on the System

The packet linear MSP protocol is stopped and MSP fails. As a result, channelized STM-1 services cannot be protected.

Possible Causes

The possible cause of this alarm is as follows:

Cause: The APS protocol for the alarmed protection group is manually stopped.

Procedure

  1. Cause: The APS protocol for the alarmed protection group is manually stopped.
    1. Determine the ID of the MSP group whose APS protocol is stopped.
    2. Restart the MSP protocol for the MSP group.
    3. Check whether the alarm is cleared. If the alarm persists, contact Huawei technical support personnel to handle the alarm.

Related Information

None