Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
WAVEDATA_MIS

WAVEDATA_MIS

Description

The WAVEDATA_MIS indicates a wavelength or band mismatch. If the operating wavelength or band differs from the configured value, the alarm is reported.

Attribute

Alarm Severity Alarm Type

Major

Equipment alarm

Parameters

None

Impact on the System

The service may be interrupted.

Possible Causes

  • Cause 1: The operating wavelength or band differs from the configured value.

  • Cause 2: The board is faulty.

Procedure

  • Cause 1: The operating wavelength or band differs from the configured value.
    1. Query the operating wavelength and configured wavelength of the board on the NMS. If the two values differ, set the wavelength consistently with the actual operating wavelength of the optical module.
  • Cause 2: The board is faulty.
    1. If the alarm persists, replace the board or optical module with another one whose operating wavelength is the same as the configured value. For details, see the Parts Replacement.