Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
SSM_LOS

SSM_LOS

Description

This alarm indicates that the SSM quality information fails to be received. In SSM mode, this alarm is reported when a reference source port configured in the priority table fails to obtain valid SSM quality information within 5 seconds.

Attribute

Alarm Severity Alarm Type

Minor

Equipment alarm

Parameters

None

Impact on the System

This alarm triggers switching of the reference clock source.

Possible Causes

  • The upstream NE sends invalid SSM quality information.
  • In SSM mode, the NE fails to obtain valid SSM quality information.

Procedure

  1. On the NMS, check whether the SSM quality information is properly sent by the upstream NE. If it is properly sent, check whether the upstream and local NEs are properly interconnected.
  2. The alarm is cleared when valid SSM quality information is received.

Related Information

None