Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
RMFA

RMFA

Description

The RMFA is an alarm that the framing E1/T1 multiframe notification event occurs. If the framing E1/T1 signals occur in consecutive Z (Z is from two through five) CAS multiframe cycles, the RMFA alarm is reported when all the CAS multiframe mutual-notification bits of the input signals are set to 1.

Attribute

Alarm Severity Alarm Type

Minor

Communication alarm

Parameters

None

Impact on the System

When the RMFA alarm occurs, the services at the local station are not affected. This alarm just shows that the LMFA alarm occurs at the opposite station.

Possible Causes

The possible cause of the RMFA alarm is as follows:

The LMFA alarm occurs at the remote end.

Procedure

  1. Check whether the LMFA alarm occurs at the opposite end of the path corresponding to the board that reports the alarm. If yes, clear the LMFA alarm at the opposite end. Then the RMFA alarm at the local end is cleared accordingly.