Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
IN_PWR_HIGH

IN_PWR_HIGH

Description

The IN_PWR_HIGH alarm indicates that the actual input optical power is higher than the upper threshold of the input power reference value.

Attribute

Alarm Severity Alarm Type

Critical

Equipment

Parameters

None

Impact on the System

Bit errors occur in the services at optical ports. Over high input power also causes damages to the laser.

Possible Causes

Possible causes of this alarm are as follows:

  • Cause 1: The transmit power of the opposite end is over high.
  • Cause 2: Inapplicable optical modules are used.
  • Cause 3: The optical module at the receive end is faulty.

Procedure

  1. Cause 1: The transmit power of the opposite end is over high.
    1. On the NMS, follow the instructions in Querying the Optical Power to check whether the output power of the board connected to the alarm board is higher than that listed in Specifications of Optical/Electrical Modules.

      If...

      Then...

      The output power is higher than that listed in Specifications of Optical/Electrical Modules

      Add a proper attenuator at the receive end, and check whether the alarm is cleared. If the alarm persists, go to 2.

      The output optical power is normal

      Go to 2.

  2. Cause 2: Inapplicable optical modules are used.
    1. Check whether applicable optical modules are used at both receive and transmit ends based on the transmission distance.

      If...

      Then...

      Inapplicable optical modules are used

      Replace the optical modules or board.

      Applicable optical modules are used

      Go to 3.

  3. Cause 3: The optical module at the receive end is faulty.
    1. Replace the optical module or board at the receive end.
    2. Check whether alarm is cleared. If the alarm persists, contact Huawei technical support personnel to handle the alarm.