Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Alarm List P

Alarm List P

This section lists alarms starting with P.

Name Description Severity Applicable Equipment
P_AIS Indicates that the received signals on the PDH side of the E3/T3 tributary board are all 1s. Major OptiX OSN 550/580
P_LOC Indicates loss of the input signals on the PDH side of the E3/T3 tributary board. Major OptiX OSN 550/580
P_LOS Indicates loss of signal on the PDH side of the E3/T3 tributary board in the receive direction. Major OptiX OSN 550/580
PASSWORD_NEED_CHANGE Indicates that the default user's default password is not changed. Major OptiX OSN 550/500/580
PATCH_CHGSCC_NOTMATCH Indicates that the versions of patch packages on service boards are different from the version of the patch package on the SCC board after the SCC board is replaced. Major OptiX OSN 550/500/580
PATCH_BD_EXCLUDE Indicates that a board is isolated because a patch package cannot be installed on it. Major OptiX OSN 550/500/580
PATCH_BD_MATCH_FAIL Indicates that a patch package fails to be installed on a board. Major OptiX OSN 550/500/580
PATCH_MATCH_NO_START Indicates that the system control board does not initiate board patch matching. Minor OptiX OSN 550/500/580
PATCH_PKGERR Indicates that the patch package file is abnormal. Minor OptiX OSN 550/500/580
PATCH_OP_TIMEOUT Indicates that a patch package operation times out. Minor OptiX OSN 550/500/580
PATCH_INIT_FAIL Indicates that patch initialization fails. Major OptiX OSN 550/500/580
PCM_64KSNCP_UNAVAIL Indicates that 64K subnetwork connection protection (SNCP) is unavailable. Major OptiX OSN 550
PCM_DATA_CONFLICT Indicates a data conflict of multiplexer group members. Major OptiX OSN 550/580
PING_ARP_MISMATCH Indicates that the dynamic ARP and static ARP conflict in the ping operation. Minor OptiX OSN 580/550/500
PING_LOS Indicates that IP Ping fails. Minor OptiX OSN 580/550/500
PORT_EXC_TRAFFIC Indicating that the traffic over an Ethernet port exceeds its threshold. Major OptiX OSN 550/500/580
PORT_MODULE_OFFLINE Indicates that the optical module on an optical port is offline. Major OptiX OSN 550/580
PORTMODE_MISMATCH Indicates that the working mode of the opposite FE port does not match with that of the local FE port. Minor OptiX OSN 550/500/580
POWER_ABNORMAL Indicates that the power supply is abnormal. Major OptiX OSN 550/500
POWER_FAIL Indicates a power supply failure on an NE. Major OptiX OSN 550/500/580
POWER_MODULE_OFFLINE Indicates that a power module is offline. Major OptiX OSN 550
PRO_PKT_FLOODING Indicates the NE is under a flooding attack of protocol packets. Major OptiX OSN 550/500/580
PPP_LCP_FAIL Indicates a Link Control Protocol (LCP) negotiation failure. Major OptiX OSN 550/500
PPP_NCP_FAIL Indicates a Network Control Protocol (NCP) negotiation failure. Major OptiX OSN 550/500
PRBS_LSS Indicates loss of the pseudo-random binary sequence (PRBS) signal. Minor OptiX OSN 580
PTP_ATTR_MISMATCH Indicates the Precision Time Protocol (PTP) port attributes are inconsistent at both ends. Minor OptiX OSN 580
PTP_DECRYPTION_FAIL Indicates that packets returned on an IEEE 1588 ring network fail to be decrypted. Major OptiX OSN 580
PTP_DELAY_RESP_LOS Indicates that Delay_Resp packets are lost. Major OptiX OSN 580
PTP_PDELAY_RESP_LOS Indicates that Pdelay_Resp packets are lost. Major OptiX OSN 580
PTP_SYNC_LOS Indicates that SYNC packets are lost. Major OptiX OSN 580
PTP_SOURCE_SWITCH Indicating that the PTP clock source is switched. Minor OptiX OSN 550
PTP_TIMESTAMP_ABN Indicating an abnormality of the PTP timestamp. Major OptiX OSN 550/580
PTPSRV_LCS_INVALID Indicating that the service license for the PTP clock is invalid. Warning OptiX OSN 550
PUM_BCM_ALM Working current of pump laser over threshold Major OptiX OSN 550/580
PUM_TEM_ALM The operating temperature of the pump laser exceeds the threshold Major OptiX OSN 550/580
PUMP_COOL_EXC Cooling current of pump laser over threshold Critical OptiX OSN 550/580
PW_NO_TRAFFIC Indicates that a PW does not receive or transmit any traffic. Critical OptiX OSN 550/500
PW_APS_DEGRADED Indicates that a PW APS protection group degrades. Major OptiX OSN 550/500/580
PW_APS_OUTAGE Indicates that a PW APS protection group fails. Major OptiX OSN 550/500/580
PWAPS_LOST Indicates that the APS frames are lost. Minor OptiX OSN 550/500/580
PWAPS_PATH_MISMATCH Indicates that the local NE and the opposite NE are configured with different working and protection paths of the PW APS protection group. Major OptiX OSN 550/500/580
PWAPS_SWITCH_FAIL Indicates a switching failure in the PW APS protection group. Minor OptiX OSN 550/500/580
PWAPS_TYPE_MISMATCH Indicates that the local NE and the opposite NE are configured with different PW protection types. Major OptiX OSN 550/500/580
PWD_ENCRYPT_RISK The user password encryption mode of an NE has security risks. Major OptiX OSN 550/500/580
PWR_MAJ_ALM Power supply overvoltage or undervoltage. Critical OptiX OSN 550
PWR_TEMP_OVERTH Indicates that the temperature of the power module crosses the specified threshold. Critical OptiX OSN 550/500