Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
PORT_MODULE_OFFLINE

PORT_MODULE_OFFLINE

Description

This alarm indicates that the optical module on an optical port is offline. This alarm is generated when the board detects that an optical module is offline.

Attribute

Alarm Severity Alarm Type

Major

Equipment alarm

Parameters

None

Impact on the System

Absence of the optical module leads to an interruption of services through by the corresponding optical port.

Fault Symptom

None

NOTE:

If the fault has no symptom, or if the fault symptom is different from the one described in this topic, handle the fault according to "Handling Procedure" provided in this topic.

Possible Causes

  • Cause 1: The optical module does not exist or is not correctly inserted in the optical port.

  • Cause 2: The optical module or the board is faulty.

Procedure

  • Check the alarm information on the NMS and record the IDs of the port and channel where the alarm is generated.
  • Cause 1: The optical module does not exist or is not correctly inserted in the slot.
    1. Check whether the optical port where this alarm is generated has an optical module.

      If...

      Then...

      The optical port has no optical module.

      Insert an optical module into the optical port properly.

      The optical port has an optical module.

      See the alarm handling procedure for cause 2.

  • Cause 2: The optical module or the board is faulty.

    If...

    Then...

    The board supports pluggable optical modules

    Replace pluggable optical modules. For details, see Replacing the Optical Module. If the alarm persists, replace the faulty board.

    The board does not support pluggable optical modules

    Reset the board. For details, see Resetting Boards.

    If the alarm persists, replace the faulty board.

Related Information

None