OSN 500 550 580 V100R008C50 Alarms and Performance Events Reference 02

Rate and give feedback :
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
BD_VER_NOT_MATCH

BD_VER_NOT_MATCH

Description

The BD_VER_NOT_MATCH alarm indicates a board version mismatch.

Attribute

Alarm Severity Alarm Type

Major

Communication alarm

Parameters

When you view an alarm on the network management system, select the alarm. In the Alarm Details field display the related parameters of the alarm. The alarm parameters are in the following format: Alarm Parameters (hex): parameter1 parameter2...parameterN. For details about each parameter, refer to the following table.

Name Meaning

Parameter 1, Parameter 2

Indicate the slot ID.

Parameter 3

Indicates the version that is different from that specified in the version mapping table.

  • 0x01: extended BIOS version
  • 0x02: board software version
  • 0x03: FPGA version
  • 0x04: BIOS version
  • 0x05: PCB version

Impact on the System

Certain functions fail.

Possible Causes

The possible causes of the BD_VER_NOT_MATCH alarm are as follows:

  • Cause 1: The board software, FPGA, BIOS, or extended BIOS version does not match that specified in the version mapping table.

  • Cause 2: The board PCB version does not match that specified in the version mapping table.

Procedure

  1. Cause 1: The board software, FPGA, BIOS, or extended BIOS version does not match that specified in the version mapping table.
    1. Upgrade or downgrade the board software, FPGA, BIOS, or extended BIOS to a correct version and warm reset the board.
    2. Check whether the alarm is cleared. If the alarm persists, go to 2.
  2. Cause 2: The board PCB version does not match that specified in the version mapping table.
    1. Replace the PCB module with a new one of a correct version.
    2. Check whether the alarm is cleared. If the alarm persists, contact Huawei technical support engineers to handle the alarm.