Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Alarm List L

Alarm List L

This section lists alarms starting with L.

Name Description Severity Applicable Equipment
LAG_DOWN Indicates that a link aggregation group (LAG) is unavailable. Major OptiX OSN 550/500/580
LAG_MEMBER_DOWN Indicates that a member port of a LAG is unavailable. Minor OptiX OSN 550/500/580
LAG_PORT_FAIL Indicating that a port in the LAG fails. Minor OptiX OSN 550/580
LASER_CHECK_ERR Indicates that an optical module reading/writing error occurs. Minor OptiX OSN 550/580
LASER_CLOSED Indicates that the user issues the command of shutting down the laser and the laser of the line board is in the close status. Major OptiX OSN 550/580
LASER_MOD_ERR Indicates mismatch of optical modules. Major OptiX OSN 550/500/580
LASER_MOD_ERR_EX Indicates that the pluggable optical module on the line board does not match the optical port of the line board. Major OptiX OSN 550/580
LASER_MODULE_MISMATCH Indicates a mismatch of the optical module type and the fiber type. Major OptiX OSN 580
LASER_SHUT Indicates that the laser of the board is shut down. Major OptiX OSN 550/500/580
LASER_TYPE_MISMATCH Indicates that the optical module type does not match. Major OptiX OSN 580
LCAS_FOPR Indicating the protocol failure in the LCAS receive direction. Attribute Major OptiX OSN 550/580
LCAS_FOPT Indicating the protocol failure in the LCAS transmit direction. Major OptiX OSN 550/580
LCAS_PLCR Indicating the loss of partial bandwidth in the LCAS receive direction. Minor OptiX OSN 550/580
LCAS_PLCT Indicating the loss of partial bandwidth in the LCAS transmit direction. Minor OptiX OSN 550/580
LCAS_TLCR Indicating the loss of all bandwidth in the LCAS receive direction. Major OptiX OSN 550/580
LCAS_TLCT Indicating the loss of all bandwidth in the LCAS transmit direction. Major OptiX OSN 550/580
LCD Indicates loss-of-cell delimitation. Major OptiX OSN 550/500/580
LCS_DAYS_OF_GRACE Indicates that a license file remains in the grace period. Major OptiX OSN 550/500/580
LCS_EXPIRED Indicates that a license file expires. Critical OptiX OSN 550/500/580
LCS_FILE_NOT_EXIST Indicates that the License file is not installed on the NE. Critical OptiX OSN 550/500/580
LFA Indicates loss of E1 basic frame alignment. Major OptiX OSN 550/500/580
LINK_ERR Indicates that the data link is incorrect. Critical OptiX OSN 550/580
LMFA Indicates loss of multiframe alignment. Major OptiX OSN 550/500/580
LOF_64K indicates that the local end carrying 64 kbit/s services does not receive any frames or frame alignment signals from the remote end. Major OptiX OSN 550/580
LOOP_ALM Indicates a loopback alarm. Minor OptiX OSN 550/500/580
LP_CROSSTR Indicates that the number of the lower order path bit errors crosses the threshold. Minor OptiX OSN 550/580
LP_R_FIFO Indicates that the FIFO messages on the receive side of the lower order path overflow. Minor OptiX OSN 550/580
LP_RDI Indicates the remote defect in the lower order path of the tributary board. Minor OptiX OSN 550/580
LP_RDI_VC12 Indicates the remote defect in the lower order path of the tributary board. Minor OptiX OSN 550/580
LP_RDI_VC3 Indicates the remote defect in the lower order path of the tributary board. Minor OptiX OSN 550/580
LP_REI Indicates the remote error indication alarm in the lower order path. Minor OptiX OSN 550/580
LP_REI_VC12 Indicates the remote bit error in the lower order path of the tributary board. Minor OptiX OSN 550/580
LP_REI_VC3 Indicates the remote bit error in the lower order path of the tributary board. Minor OptiX OSN 550/580
LP_RFI Indicates the remote failure indication alarm in the lower order path. Minor OptiX OSN 550/580
LP_SIZE_ERR Indicates the TU specification error alarm. Minor OptiX OSN 550/580
LP_SLM Indicates signal label mismatch in the lower order path. Minor OptiX OSN 550/580
LP_SLM_VC12 Indicates the VC-12 lower order path signal label mismatch. Minor OptiX OSN 550/580
LP_SLM_VC3 Indicates the VC-3 lower order path signal label mismatch. Minor OptiX OSN 550/580
LP_T_FIFO Indicates that the FIFO messages on the transmit side of the lower order path overflow. Minor OptiX OSN 550/580
LP_TIM Indicates trace identifier mismatch in the lower order path. Minor OptiX OSN 550/580
LP_TIM_VC12 Indicates the VC-12 lower order path trace identifier mismatch. Minor OptiX OSN 550/580
LP_TIM_VC3 Indicates the VC-3 lower order path trace identifier mismatch. Minor OptiX OSN 550/580
LP_UNEQ Indicates that no payload is equipped in the lower order path. Minor OptiX OSN 550/580
LP_UNEQ_VC12 Indicates the VC-12 lower order path unequipped. Minor OptiX OSN 550/580
LP_UNEQ_VC3 Indicates the VC-3 lower order path unequipped. Minor OptiX OSN 550/580
LPS_UNI_BI_M Indicates mismatch of the single-ended and dual-ended modes in a linear MSP. Minor OptiX OSN 550/580
LPT_AUTH_FAIL Indicates that LPT authentication fails. Major OptiX OSN 550/500/580
LPT_CFG_CLOSEPORT Indicates that the LPT closes a service port. Major OptiX OSN 550/500/580
LPT_RFI Indicates the remote failure indication of Link state pass-through (LPT). Critical OptiX OSN 550/580
LSR_COOL_ALM Indicates that the cooling current of the laser crosses the threshold. Major OptiX OSN 580
LSR_BCM_ALM Indicates that the bias current of the laser crosses the thresholds. Major OptiX OSN 550/500/580
LSR_NO_FITED Indicates that the pluggable optical module of the line board is not installed. Critical OptiX OSN 550/500/580
LSR_WILL_DIE Indicates that the life of the laser is close to the end. Critical OptiX OSN 550/500/580
LTI Indicates loss of synchronization clock sources set for the clock board. Major OptiX OSN 550/500/580