Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
NESOFT_MM

NESOFT_MM

Description

The NESOFT_MM alarm indicates that the NE software versions in the active and standby system control units are inconsistent.

Attribute

Alarm Severity Alarm Type

Major

Processing alarm

Parameters

When you view an alarm on the network management system, select the alarm. In the Alarm Details field display the related parameters of the alarm. The alarm parameters are in the following format: Alarm Parameters (hex): parameter1 parameter2...parameterN. For details about each parameter, refer to the following table.

Name Meaning

Parameter 1

  • 0x01: files in the flash memory
  • 0x02: software that is running

Parameter 2 and Parameter 3

Indicate the IDs of inconsistent files in the active system control unit.

Parameter 4

Indicates the alarm cause.

  • 0x04: The versions of files in the active and standby areas (OFS1 and OFS2) of a system control unit are inconsistent.
  • 0x08: The versions of files in the active and standby system control units are inconsistent, or the files in the corresponding directories of the active and standby system control units have different names.
  • 0x0C: The versions of files in the active and standby areas of a system control unit are inconsistent, and the versions of files in the active and standby system control units are inconsistent.

Impact on the System

  • The active/standby switching of the system is affected.
  • If the NE software does not exist in the flash memory, the system cannot restart after the system is powered off or reset.

Possible Causes

Possible causes of this alarm are as follows:

  • The versions of the software running in the active and standby system control units are inconsistent.
  • The versions of the software in the active and standby areas (OFS1 and OFS2) are inconsistent.
  • The files in the corresponding directories of the active and standby system control units have different names.

Procedure

  1. Contact Huawei technical support engineers to reload the required software.

Related Information

None.