Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
LP_T_FIFO

LP_T_FIFO

Description

The LP_T_FIFO alarm indicates that FIFO overflow on the transmit side of the lower order path.

Attribute

Alarm Severity Alarm Type

Minor

Equipment alarm

Parameters

When you view an alarm on the network management system, select the alarm. In the Alarm Details field display the related parameters of the alarm. The alarm parameters are in the following format: Alarm Parameters (hex): parameter1 parameter2...parameterN. For details about each parameter, refer to the following table.

Name Meaning

Parameter 1

This parameter is ineffective. It has a fixed value of 0x01.

Parameter 2, Parameter 3

Indicates the path ID.

Impact on the System

Bit errors occur in lower order services of the board.

Possible Causes

Possible causes of this alarm are as follows:

  • The service cross-connections are incorrectly configured.
  • The services received by the board are incorrect.

Procedure

  1. View the LP_T_FIFO alarm on the U2000, and check whether the service configurations on the board that reports the LP_T_FIFO alarm and the NE are correct. If the service configurations are incorrect, modify the service configurations and check whether the alarm is cleared.
  2. If the alarm persists, check whether the services received by the board are correct. After ensuring that the services are correct, check whether the alarm is cleared.
  3. If the alarm persists, replace the board.

Related Information

None.