No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

OSN 500 550 580 V100R008C50 Alarms and Performance Events Reference 02

Rate and give feedback :
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
UHCS

UHCS

Description

The UHCS alarm indicates that multiple uncorrectable bit errors occur in the cell header.

Attribute

Alarm Severity Alarm Type

Minor

Communication alarm

Parameters

None.

Impact on the System

When the UHCS alarm is reported, some cells with multiple bit errors are found during cell the delimitation process at the port. Consequently, user cells are lost.

Possible Causes

Possible causes of the UHCS alarm are as follows:

  • Some bit errors occur in the SDH receive path connected to an ATM port on the alarmed board. That is, some bit error alarms, such as the B1_SD, B2_SD, or B3_SD, occur in the SDH path.
  • The ATM processing chip on the alarmed board is faulty.

Procedure

  1. On the U2000, check whether alarms indicating that the signal degrades due to excessive errors, such as B1_SD, B2_SD, and B3_SD, are reported at the local NE.
    If... Then...

    The alarms are reported

    Handle the alarms, and check whether the UHCS alarm is cleared. If the UHCS alarm persists, go to the next step.

    The alarms are not reported

    Go to the next step.

  2. Reset (cold) or reseat the board that reports the UHCS alarm, and then check whether the UHCS alarm is cleared.

    If the services on the alarmed board are not protected, a cold reset on the board causes service interruption.

    If... Then...

    The UHCS alarm is cleared

    No further action is required.

    The UHCS alarm persists

    Go to the next step.

  3. Replace the board that reports the UHCS alarm.

Related Information

None.