No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

OSN 500 550 580 V100R008C50 Alarms and Performance Events Reference 02

Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
PATCH_BD_MATCH_FAIL

PATCH_BD_MATCH_FAIL

Description

The PATCH_BD_MATCH_FAIL is an alarm indicating a board patch mismatch. An NE reports the PATCH_BD_MATCH_FAIL alarm if the patch software of a board fails to match with the patch package software on the system control board for three consecutive times after patch package loading completes.

Attribute

Alarm Severity Alarm Type

Major

Equipment

Parameters

None

Impact on the System

If the system control board reports a PATCH_BD_MATCH_FAIL, patch package loading may fail again. If another board reports a PATCH_BD_MATCH_FAIL alarm, the NE housing the board may report a PATCH_BD_MATCH_FAIL alarm again.

Possible Causes

The possible causes of the PATCH_BD_MATCH_FAIL alarm are as follows:

  • Cause 1: Board communication faults occur.
  • Cause 2: The board software is abnormal.

Procedure

  1. Cause 1: Board communication faults occur.
    1. On the NMS, check whether communication fault alarms such as COMMUN_FAIL are reported. If any, clear the alarms.
    2. Then, check whether the PATCH_BD_MATCH_FAIL alarm is cleared. If the alarm persists, go to 2.
  2. Cause 2: The board software is abnormal.
    1. On the NMS, manually isolate the board and rectify the board software fault.
    2. Restart matching between the board patch software and the patch package software on the system control board.
    3. Check whether the alarm is cleared. If the alarm persists, contact Huawei engineers to handle the alarm.

Related Information

None