Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Alarm List H

Alarm List H

This section used a table to list the alarms starting with H.

Name Description Severity Applicable Equipment
HARD_BAD Indicates a board hardware failure. Critical OptiX OSN 550/500/580
HARD_ERR Indicates a hardware error. Minor OptiX OSN 580
HARD_NONSUPPORT Indicating that a certain function is not supported by a board. Major OptiX OSN 550/500/580
HP_CROSSTR Indicates that the HP performance crosses the threshold. Minor OptiX OSN 550/580
HP_LOM Indicates HP loss of multiframe. Major OptiX OSN 550/580
HP_R_FIFO Indicates that the FIFO overflows on the HP receiving side. Minor OptiX OSN 550/580
HP_RDI Indicates that the local station receives a remote defect indication in the higher order path sent from the opposite station Minor OptiX OSN 550/500/580
HP_REI Indicates that the local station receives the remote bit error in the higher order path sent from the opposite station. Warning OptiX OSN 550/500/580
HP_SLM Indicates mismatch of the higher order path signal label (C2) received by the line board. Minor OptiX OSN 550/500/580
HP_T_FIFO Indicates that the FIFO overflows at the transmit side of the line higher order path. Minor OptiX OSN 550/580
HP_TIM Indicates mismatch of the higher order path trace identifier (J1) received by the line board. Minor OptiX OSN 550/500/580
HP_UNEQ Indicates that the higher order path received by the line board is unloaded. Minor OptiX OSN 550/500/580
HPAD_CROSSTR Indicates that the performance of the higher order path adaptation crosses the threshold. Minor OptiX OSN 550/580
HSC_UNAVAIL Indicates an abnormal hot-backup state. Minor OptiX OSN 550/580
HPS_WP_LATEN_DIFF Indicates that the delay difference between the working and protection paths of the hitless protection group exceeds the threshold. Minor OptiX OSN 550/580
HPS_WP_LATEN_JITTER Indicates that the delay jitter in the working or protection path (long or short path) of the hitless protection group exceeds the threshold. Minor OptiX OSN 550/580
Translation
Download
Updated: 2019-01-21

Document ID: EDOC1100020975

Views: 76026

Downloads: 138

Average rating:
This Document Applies to these Products
Related Documents
Related Version
Share
Previous Next