OSN 500 550 580 V100R008C50 Alarms and Performance Events Reference 02

Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
NO_BD_SOFT

NO_BD_SOFT

Description

The NO_BD_SOFT is an alarm indicating that the software of the service board is damaged or does not exist.

Attribute

Alarm Severity Alarm Type

Critical

Equipment alarm

Parameters

When you view an alarm on the network management system, select the alarm. In the Alarm Details field display the related parameters of the alarm. The alarm parameters are in the following format: Alarm Parameters (hex): parameter1 parameter2...parameterN. For details about each parameter, refer to the following table.

Name Meaning

Parameter 1

The value is always 0x01.

Parameter 2, Parameter 3

Indicate the ID of the file that is lost.

Parameter 4

Indicate the type of the file that is lost.

  • 0x01: The file does not exist.
  • 0x02: The file check fails.
  • 0x04: The version of a file in the active area is different from the version of the corresponding file in the standby area.
  • 0x08: The version of a file on the active board is different from the version of the corresponding file on the standby board.
  • 0x0e: The file check fails. The version of a file in the active area on the active board is different from the version of the corresponding file in the standby area on the active board, and from the version of the corresponding file on the standby board.

Impact on the System

If the NO_BD_SOFT alarm occurs, no software is load to the service board of the NE, or the software is not fully loaded to the board of the NE. If the board software does not exist or is not fully loaded, the board does not work normally after being restarted.

Possible Causes

The possible causes of the NO_BD_SOFT alarm are as follows:

  • The software is lost, deleted, or not loaded.
  • The service board is damaged.

Procedure

  1. Check the alarm parameters, and determine the type of the lost file according to parameter 4. Reload the lost file. After loading the file, reset the board.
  2. View alarms on the U2000 to check whether the NO_BD_SOFT alarm is cleared.

    If... Then...
    The alarm is cleared The fault is rectified.
    The alarm persists Go to the next step.

  3. If the alarm persists, replace the board.

Related Information