Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
OPU1_MSIM

OPU1_MSIM

Description

OPU1 multiplex structure identifier mismatch.

k indicates the level of rate, its value is 0, 1, 2, or 3.

Attribute

Alarm Severity Alarm Type

Minor

Communication alarm

Parameters

None

Impact on the System

The services may be unavailable.

Possible Causes

The board does not support the multiplex structure for service transmission of the board on the source NE.

Procedure

  1. Check whether the multiplex structure of the local board mismatches that of the corresponding board on the source NE.
  2. If the multiplex structures of the two boards do not match, replace one of them with a matched board.

Related Information

None