No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

OSN 500 550 580 V100R008C50 Alarms and Performance Events Reference 02

Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
NO_ELABEL

NO_ELABEL

Description

The NO_ELABEL alarm indicates that the electronic label is unloaded.

Attribute

Alarm Severity Alarm Type

Warning

Equipment alarm

Parameters

When you view an alarm on the network management system, select the alarm. In the Alarm Details field display the related parameters of the alarm. The alarm parameters are in the following format: Alarm Parameters (hex): parameter1 parameter2...parameterN. For details about each parameter, refer to the following table.

Name Meaning

Parameter 1

System control, fan, and power boards:

  • 0x00: indicates that the electronic label of the backplane is lost.
  • Other value: indicates the ID of the board whose electronic label is lost.

Other boards:

  • 0x01: indicates that the electronic label of the board is lost.
  • 0x03: indicates that the electronic label of the optical module is lost.

Parameter 2

System control, fan, and power boards: This parameter does not exist.

Other boards: The parameter value is fixed at 0x01.

Parameter 3

System control, fan, and power boards: This parameter does not exist.

Other boards:

  • If parameter 1 is 0x01, the value of parameter 3 is fixed at 0x01.
  • If parameter 1 is 0x03, parameter 3 indicates the ID of the optical port.

Impact on the System

None

Possible Causes

The electronic label is unloaded or lost.

Procedure

  1. Check whether the electronic label of the backplane, board, or optical module is faulty based on alarm parameters.
  2. If the electronic label of the board or optical module is faulty, replace the board or optical module.
  3. If the electronic label of the backplane is faulty, replace the chassis.
  4. If the alarm persists, contact Huawei technical support personnel to handle the alarm.

Related Information