Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
FDBSIZEALM_ELAN

FDBSIZEALM_ELAN

Description

The FDBSIZEALM_ELAN alarm indicates that the E-LAN forwarding table entries are exhausted. This alarm is reported when the number of the MAC table entries of the E-LAN service exceeds the value of Address Detection Upper Threshold and is cleared after the number is smaller than the value of Address Detection Upper Threshold.

Attribute

Alarm Severity Alarm Type

Minor

Service alarm

Parameters

None

Impact on the System

The E-LAN service stops learning new MAC addresses. As a result, unknown unicast packets in the traffic flow may increase, and the broadcast packets may increase accordingly, affecting the line rate.

Possible Causes

Possible causes of this alarm are as follows:

  • Cause 1: The value of Address Detection Upper Threshold is too small.
  • Cause 2: The E-LAN service is attacked.

Procedure

  1. Cause 1: The value of Address Detection Upper Threshold is too small.
    1. On the NMS, check whether the value of Address Detection Upper Threshold is too small.
    2. If the value is too small, set the parameter to a larger value based on the actual situations. Check whether the alarm is cleared. If the alarm persists, go to 2.
  2. Cause 2: The E-LAN service is attacked.
    1. On the NMS, set the processing mode of E-LAN service for the unknown frames to discard.
    2. Check whether the alarm is cleared. If the alarm persists, contact Huawei technical support personnel to handle the alarm.