OSN 500 550 580 V100R008C50 Alarms and Performance Events Reference 02

Rate and give feedback :
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
LCAS_TLCR

LCAS_TLCR

Description

The LCAS_TLCR is an alarm indicating the loss of all bandwidth in the LCAS receive direction.

Attribute

Alarm Severity Alarm Type

Major

Service quality alarm

Parameters

When you view an alarm on the network management system, select the alarm. In the Alarm Details field display the related parameters of the alarm. The alarm parameters are in the following format: Alarm Parameters (hex): parameter1 parameter2...parameterN. For details about each parameter, refer to the following table.

Name Meaning

Parameter 1

Indicates the optical interface number. The value is always 0x01.

Parameter 2, Parameter 3

Indicates the VCTRUNK port number.

Impact on the System

The paths configured in the receive direction are not used, so the available bandwidth is zero.

Possible Causes

The possible causes of the LCAS_TLCR alarm are as follows:

  • When the LCAS function of the VCTRUNK is enabled, in the receive direction, the number of paths that carry load is zero, whereas the number of paths configured is not zero.

Procedure

  1. Check the service configurations of the local and opposite station. Check whether the bound paths of the VCTRUNK are consistent. If any error exists, reconfigure the values.
  2. Check whether the configured path reports SDH alarms. If yes, see the handling procedure of the corresponding alarm.

Related Information

None