Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
T_FIFO_E

T_FIFO_E

Description

The T_FIFO_E alarm indicates that the transmit FIFO on the PDH side of the E3/T3 tributary board overflows.

Attribute

Alarm Severity Alarm Type

Minor

Equipment alarm

Parameters

None.

Impact on the System

The alarmed port has bit errors and the services at the port are unavailable.

Possible Causes

Possible causes of this alarm are as follows:

  • Incorrect services are accessed into the E3/T3 tributary board.
  • Service cross-connections are incorrectly configured.
  • The E3/T3 tributary board is faulty.
  • The cross-connect and timing board is faulty.

Procedure

  1. Check whether correct services are accessed into the E3/T3 tributary board on the NMS.

    If... Then...

    Incorrect services are accessed

    Configure correct services to be accessed into the E3/T3 tributary board. Check whether the alarm is cleared. If the alarm persists, go to the next step.

    Correct services are accessed

    Go to the next step.

  2. Replace the E3/T3 tributary board and ensure that the new board transmits and receives the same types of signals as the old board.

    Replacing the E3/T3 tributary board will interrupt the services on the board. This operation is of risk.

  3. If the alarm persists, replace the cross-connect and timing board.

Related Information