Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
MOD_TYPE_MISMATCH

MOD_TYPE_MISMATCH

Description

The MOD_TYPE_MISMATCH is an alarm indicating that a mismatched port module is detected.

Attribute

Alarm Severity Alarm Type

Critical

Equipment alarm

Parameters

When you view an alarm on the network management system, select the alarm. In the Alarm Details field display the related parameters of the alarm. The alarm parameters are in the following format: Alarm Parameters (hex): parameter1 parameter2...parameterN. For details about each parameter, refer to the following table.

Name Meaning
Parameter 1

Indicates the ID of the port that reports the alarm. For example, Parameter 1 = 0x01 indicates that the alarm is reported by port 1 of the related board.

Parameter 2, Parameter 3

Parameter 2 is always 0x00, and Parameter 3 is always 0x01. These parameters are meaningless.

Impact on the System

The services carried over the port are interrupted.

Possible Causes

The possible causes of the MOD_TYPE_MISMATCH alarm are as follows:

The type of the SFP module is different from the equipment module type.

Procedure

  1. Based on the alarm parameters, locate the port that reports the alarm.
  2. Verify the type of the SFP module that connects to the port.
  3. If the type defined for the SFP module is wrong, replace the SFP module.
  4. If the alarm persists, contact Huawei technical support personnel to handle the alarm.

Related Information

None.