Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Alarm List R

Alarm List R

This section used a table to list the alarms starting with R.

Name Description Severity Applicable Equipment
R_APS Indicates that the line board failed to receive the K1/K2 byte. Minor OptiX OSN 550/580
R_LOC Indicates loss of the clock in the signals received by the line board at the optical port. Critical OptiX OSN 550/580
R_LOF Indicates loss of frame in the signals received by the line board at the optical port. Critical OptiX OSN 550/580
R_LOS Indicates loss of signal at the receive optical port on the line board. Critical OptiX OSN 550/580
R_OOF Indicates that the frame header cannot be identified for five consecutive frames in the received signals of the line board. Critical OptiX OSN 550/580
R_S_ERR Indicates that the received signal has errors. Critical OptiX OSN 550/580
RELAY_ALARM_CRITICAL Indicates critical alarm inputs. Critical OptiX OSN 550/500/580
RELAY_ALARM_IGNORE Indicates warning alarm inputs. Warning OptiX OSN 550/500/580
RELAY_ALARM_MAJOR Indicates major alarm inputs. Major OptiX OSN 550/500/580
RELAY_ALARM_MINOR Indicates minor alarm inputs. Minor OptiX OSN 550/500/580
RELAY_LOF Indicates that the receiving frames of the dry contact signal transmission are lost. Major OptiX OSN 550/580
RFA Indicates that the framing E1/T1 frame notification event occurs. Minor OptiX OSN 550/580
RMFA Indicates that the framing E1/T1 multiframe notification event occurs. Minor OptiX OSN 550/580
RS_CROSSTR Indicates that the regenerator section performance of the line board crosses the threshold. Minor OptiX OSN 550/580
RTC_FAIL Indicates a real-time clock (RTC) failure on the system control, switching, and timing board. Major OptiX OSN 550/500/580
RTS Indicates that the Request To Send status of the DCE is abnormal. Major OptiX OSN 550/580