Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Alarm List V

Alarm List V

This section used a table to list the alarms starting with V.

Name Description Severity Applicable Equipment
V5_VCAIS Indicates that bits 5-7 of the V5 byte in the lower order VC-12 path are all "1"s. Major OptiX OSN 550/500/580
VC_AIS Indicates a virtual channel (VC) connection alarm. Critical OptiX OSN 550/500
VC_LOC Indicates loss of connectivity on the VC. Major OptiX OSN 550/500
VCAT_LOA Indicating that the virtual concatenation time delay crosses the threshold. Critical OptiX OSN 550/580
VCAT_LOM_VC12 Indicates that multiframe of the VC-12 virtual concatenation is lost. Major OptiX OSN 550/580
VCAT_LOM_VC3 Indicates multiframe of the VC-3 virtual concatenation is lost. Major OptiX OSN 550/580
VCAT_LOM_VC4 Indicates that multiframe of the VC-4 virtual concatenation is lost. Major OptiX OSN 550/580
VCAT_SQM_VC12 Indicates SQ mismatch of the VC-12 virtual concatenation. Major OptiX OSN 550/580
VCAT_SQM_VC3 Indicates SQ mismatch of the VC-3 virtual concatenation. Major OptiX OSN 550/580
VCAT_SQM_VC4 Indicates that the sequence numbers of the members in the VC-4 virtual concatenation do not match each other. Major OptiX OSN 550/580
VC_RDI Indicates a remote defect in the VC connection. Major OptiX OSN 550/500
VCTRUNK_NO_FLOW Indicating that the VCTRUNK port has no traffic. Major OptiX OSN 550/580
VP_AIS Indicates an alarm in the virtual channel (VP) connection. Critical OptiX OSN 550/500
VP_LOC Indicates loss of connectivity on the VP. Major OptiX OSN 550/500
VP_RDI Indicates a remote defect in the VP connection. Major OptiX OSN 550/500