Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
SWDL_NEPKGCHECK

SWDL_NEPKGCHECK

Description

The SWDL_NEPKGCHECK alarm indicates that software package files are lost. This alarm is reported when the NE software detects that some files in the CF card or flash memory are lost after performing periodic checks, which are not initiated by commands.

Attribute

Alarm Severity Alarm Type

Critical

Processing alarm

Parameters

None.

Impact on the System

When this alarm occurs, a certain file of the package is missing and the NE may malfunction.

Possible Causes

The possible cause of the SWDL_NEPKGCHECK alarm is as follows:

Certain files of the package are missing and cannot be recovered.

Procedure

  1. Ensure that the loaded software package is correct. Perform the package loading or package diffusion again on the NE where the SWDL_NEPKGCHECK alarm is reported.

Related Information

None.