Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
DDN_RFA

DDN_RFA

Description

The DDN_RFA is a remote frame alignment alarm of the framed E1 services on the DDN side of a board. When the RDI bit is set to 1 for the E1 signals received on the DDN side of a board from the opposite end, the DDN_RFA alarm is reported.

Attribute

Alarm Severity Alarm Type

Minor

Communication alarm

Parameters

None

Impact on the System

When the DDN_RFA alarm occurs, the services at the local station are not affected. This alarm just shows that the DDN_LFA alarm is received at the opposite end.

Possible Causes

The possible cause of the DDN_RFA alarm is as follows:

The DDN_LFA alarm is received at the opposite end.

Procedure

  1. After you clear the DDN_LFA alarm received at the opposite end, the DDN_RFA alarm is automatically cleared.

Related Information

None.