Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Alarm List B

Alarm List B

This section used a table to list the alarms starting with B.

Name Description Severity Applicable Equipment
B1_EXC Indicates that the number of regenerator section B1 bit errors in signals received by the line board crosses the threshold. Minor OptiX OSN 550/580
B1_SD Indicates that regenerator section B1 signals received by the line board are degraded. Minor OptiX OSN 550/580
B2_EXC Indicates that the number of multiplex section B2 bit errors in signals received by the line board crosses the threshold. Major OptiX OSN 550/580
B2_SD Indicates that multiplex section B2 signals received by the line board are degraded. Minor OptiX OSN 550/580
B3_EXC Indicates that the number of higher order B3 bit errors in signals received by the line board crosses the threshold. Major OptiX OSN 550/580
B3_EXC_VC3 Indicates that B3 bit errors in a VC-3 path cross the threshold. Major OptiX OSN 550/580
B3_EXC_VC4 Indicates that B3 bit errors in a VC-4 path cross the threshold. Major OptiX OSN 550/580
B3_SD Indicates that higher order path B3 signals received by the line board are degraded. Minor OptiX OSN 550/580
B3_SD_VC3 Indicates that B3 signals in a VC-3 path degrade. Minor OptiX OSN 550/580
B3_SD_VC4 Indicates that B3 bit errors in a VC-4 path cross the set deterioration threshold. Minor OptiX OSN 550/580
BAT1TEMP_SENSOR_FAIL Indicates that the temperature sensor of battery group 1 fails. Major OptiX OSN 550/500
BAT2TEMP_SENSOR_FAIL Indicates that the temperature sensor of battery group 2 fails. Major OptiX OSN 550/500
BD_NOT_INSTALLED Indicates that the logical board is not installed in the correct slot. Minor OptiX OSN 550/500/580
BD_STATUS Indicates that the created logical board is offline. Major OptiX OSN 550/500/580
BD_VER_NOT_MATCH Indicates a board version mismatch. Major OptiX OSN 580
BD_VER_NMAT Indicates a board version mismatch. Major OptiX OSN 550/580
BDID_ERROR Indicates that errors occur in slot verification. Major OptiX OSN 550/580
BDTEMP_SENSOR_FAIL Indicates that the temperature sensor on the board fails. Major OptiX OSN 550/500
BEFFEC_EXC Forward error correction (FEC) signals degrade. Minor OptiX OSN 580
BIOS_STATUS Indicates the BIOS status. Major OptiX OSN 550/500/580
BIP_EXC BIP excessive bit errors. Minor OptiX OSN 550/580
BIP_SD BIP signal degrade. Minor OptiX OSN 550/580
BOOTROM_BAD Indicates the BOOTROM data check failure. Major OptiX OSN 550/500/580
BRDCASTRATIO_OVER Indicates that the ratio of broadcast traffic exceeds the threshold. Major OptiX OSN 550/500
BUS_ERR Indicates a bus is abnormal. Critical OptiX OSN 550/500/580
BUS_LOC Indicates that the downstream bus clock on the tributary board is lost. Major OptiX OSN 550/580
BWUTILIZATION_OVER Indicates that bandwidth usage exceeds the threshold. Warning OptiX OSN 580