Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Alarm List N

Alarm List N

This section lists alarms starting with N.

Name Description Severity Applicable Equipment
NE_POWER_OVER Indicates that the power consumption of an NE is over the threshold. Major OptiX OSN 550/500/580
NEBD_XC_DIF Indicates that the cross-connect matrix data of the NE and board is different. Critical OptiX OSN 580
NEIP_CONFUSION Indicates that an NE IP address conflict occurs. Major OptiX OSN 550/500/580
NESF_LOST Indicates that the NE software is lost. Critical OptiX OSN 550/500/580
NESOFT_MM Indicates that the NE software versions in the active and standby system control units are inconsistent. Major OptiX OSN 550/500/580
NESTATE_INSTALL Indicates that the NE is in the installing state. Critical OptiX OSN 550/500
NO_BD_SOFT Indicating that the software of the service board is damaged or does not exist. Critical OptiX OSN 550/580
NO_BD_POWER Board not powered on. Major OptiX OSN 580
NO_BD_PARA Indicates that board parameters are not configured. Critical OptiX OSN 550/580
NO_ELABEL Indicates that the electronic label is unloaded. Warning OptiX OSN 550/580
NO_LSR_PARA_FILE Indicates that in the case of the optical module with the EEPROM being used, no laser parameter files are detected in the EEPROM of the optical module after the board is started. Major OptiX OSN 550/580
NTP_SYNC_FAIL Indicates that NTP time synchronization fails. Minor OptiX OSN 550/500/580
NULL_SEND NULL signals (with payload being "0"s) being sent out. Warning OptiX OSN 580