Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
HPFECSES

HPFECSES

Performance Event Meaning

The HPFECSES event indicates the higher-order path far end consecutive severely errored second.

Performance Event Attributes

Performance Event ID Performance Event Type

0x38

SDH performance event

Impact on the System

If bit errors occur in the services on a remote NE, identify the causes and rectify the fault immediately. Otherwise, alarms will be generated and the signal transmission quality will be affected.

Possible Causes

When a consecutive HPFESES sequence is detected, the HPFECSES event occurs. When unavailable time comes or HPFESES is absent in one second, the HPFECSES sequence ends.

External causes:

  • On the opposite equipment, the fiber performance is degraded, and the fiber has high attenuation.

  • The fiber connector is dirty or incorrect at the opposite station.
  • The opposite equipment is poorly grounded.
  • There is a severe interference source around the equipment at the opposite station.
  • The working temperature is high or low, and the opposite equipment cannot tolerate such temperature.

Equipment problems:

  • The signal attenuation on the receive side of the line board at the opposite station is excessive, or the transmit circuit at the opposite station is faulty, or the receive circuit at the local station is faulty.

  • The synchronization performance of the clock is poor at the opposite station.
  • The cross-connect unit and the line board poorly match at the opposite station.
  • The fan of the opposite equipment becomes faulty.
  • The board of the opposite equipment becomes faulty or the performance of the board is degraded.

Relevant Alarms

Alarm Name Correlation

HP_REI

Higher-order path remote error indication

HP_RDI

Remote defect indication in higher-order paths

Procedure

  1. See HPFEES.

Reference

None.