Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
LP_R_FIFO

LP_R_FIFO

Description

The LP_R_FIFO alarm indicates FIFO overflow on the receive side of the lower order path.

Attribute

Alarm Severity Alarm Type

Minor

Equipment alarm

Parameters

None.

Impact on the System

Bit errors occur in lower order services of the board.

Possible Causes

Possible causes of this alarm are as follows:

  • The service cross-connections are incorrectly configured.
  • The service type is incorrectly configured.

Procedure

  1. View the LP_R_FIFO alarm on the U2000 to determine the path ID of the board that reports the LP_R_FIFO alarm.
  2. Check whether the configurations of services in the path are correct. Ensure that the service type at the local end is the same as that at the opposite end, and the service cross-connections are correctly configured. Then, the LP_R_FIFO alarm is automatically cleared.

Related Information