Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
K1_K2_M

K1_K2_M

Description

The K1_K2_M alarm indicates inconsistency between the transmitted K1 byte and received K2 byte of a linear multiplex section protection (MSP) group.

Attribute

Alarm Severity Alarm Type

Minor

Communication alarm

Parameters

None.

Impact on the System

The automatic MSP switching may fail, and the protected services may be interrupted.

Possible Causes

Possible causes of this alarm are as follows:

  • The optical fibers are incorrectly connected.
  • The types of the MSP groups at the two ends are different.
  • The cross-connect unit is faulty.

Procedure

  1. Check whether the optical fibers are correctly connected.

    If... Then...

    The optical fibers are incorrectly connected

    Reconnect the optical fibers correctly. Then, check whether the alarm is cleared. If the alarm persists, go to the next step.

    The optical fibers are correctly connected

    Go to the next step.

  2. Check whether the types of the MSP groups at the two ends are the same (both are 1+1 or 1:N MSP groups).

    If... Then...

    The types of the MSP groups at the two ends are not the same

    Ensure that the types of the MSP groups at the two ends are the same, and restart the MSP protocols at the two ends. Then, check whether the alarm is cleared. If the alarm persists, go to the next step.

    The types of the MSP groups at the two ends are the same

    Go to the next step.

  3. Replace the faulty system control, cross-connect, and timing board.

Related Information

None.