Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
SYNC_DISABLE

SYNC_DISABLE

Description

The SYNC_DISABLE alarm indicates that the automatic synchronization function on the system control, switching, and timing boards is disabled. This alarm is reported when the automatic synchronization of the system control, switching, and timing boards is disabled. This alarm is cleared after the automatic synchronization of the system control, switching, and timing board is enabled.

Attribute

Alarm Severity Alarm Type

Minor

Processing alarm

Parameters

None.

Impact on the System

The system cannot initiate batch backup between the active and standby system control, switching, and timing boards. As a result, the data on the active and standby system control, switching, and timing boards may be different.

Possible Causes

The possible cause of the SYNC_DISABLE alarm is as follows:

The status of the automatic synchronization function on the system control, switching, and timing boards changes from enabled to disabled.

Procedure

  1. Contact Huawei technical support engineers for enabling the automatic synchronization function on the system control, switching, and timing boards. Check whether the alarm is cleared.

    If... Then...

    The alarm persists

    Replace the alarmed board and check whether the alarm is cleared. If the alarm persists, go to the next step.

    The alarm is cleared

    No further action is required.

Related Information

None.